62-11640
7–8
00015
BATTERY VOLTAGE TOO HIGH
• ACTIVATION: Voltage at the main microprocessor is greater than 17 VDC.
• UNIT CONTROL: Engine Operation: Engine and unit shutdown and alarm.
Electric Operation: Refrigeration system shutdown and alarm with PSCON still ener-
gized.
• RESET CONDITION: Auto reset after 15 minutes when the voltage at the main microprocessor is
between 11 and 14 VDC, or alarm may be manually reset using the display mounted keys or by turning
the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (refer to reset condition above). Operate the unit through the appropriate modes to see
if any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Battery
Voltage
a. Test voltage at battery with unit off. Must be between 11-16 VDC.
b. Test voltage at battery with unit running. Must be between 12-16 VDC, above unit off reading (bat-
tery charger charging).
2.
Check Battery Charger
Voltage
a. Test voltage at PCM-T3 with unit off. Must be between 11-16 VDC.
b. Test voltage at PCM-T3 with unit running. Must be between 12-16 VDC.
3.
Check Voltage At Main
Microprocessor
a. Check voltage reading at 3MM-23 & 3MM-34. Must be between 11-16 VDC.
b. Check Unit Data voltage reading. Must be within 0.5 VDC of reading obtained at 3MM-23 & 3MM-
34. If voltages are out with unit running, check Battery Charger. Refer to
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......