7–13
62-11640
00021
TECHNICIAN RESET REQUIRED
• ACTIVATION: The High Engine Temp Shutdown Configuration and/or Engine Oil Pressure Shutdown
Configuration is/are set to YES, and either Alarm 00011 - Low Engine Oil Pressure,
or
Alarm 00012 -
High Coolant Temperature has become active and shut the unit down three times within the past 2 hours.
• UNIT CONTROL: Engine Operation: Engine and unit shutdown and alarm.
Electric Operation: This alarm will not activate in Electric Operation
• RESET CONDITION: Clear the alarm from inactive alarm list. This alarm and the alarm(s) that caused it
can not be reset by turning switch OFF and then ON again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (refer to reset condition above). Operate the unit through the appropriate modes to see
if any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Determine Which Alarm Activated This
Alarm
.
a. Check active alarm list for Alarm
00011 CHECK ENGINE OIL PRESSURE
. One of these alarms will be present.
b. Follow the troubleshooting steps for the alarm(s) found, and correct the alarm condition. All alarm
conditions must be corrected.
2.
Reset
Alarm
Clear all inactive alarms. Refer to
. All alarms must be cleared to start unit.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......