7–97
62-11640
05018
CHECK POWER ENABLE CONTROL
• ACTIVATION: The Power Enable Control Circuit Feedback is sensed out of range.
• UNIT CONTROL: Engine and Electric Operation: Alarm only.
• RESET CONDITION: Auto reset when circuit is normal, or alarm may be manually reset using the display
mounted keys or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (refer to reset condition above). Operate the unit through the appropriate modes to see
if any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check PER Relay on the Power Control Module
−
Refer to
a. Check resistance of PER coil Refer to
b. Check wiring No damage, moisture, or corrosion.
05019
CHECK CDCON2 COIL
• ACTIVATION: Condenser fan motor contactor (CDCON2) circuit is shorted or open.
• UNIT CONTROL: Engine and Electric Operation: Alarm only.
• RESET CONDITION: Auto Reset or alarm may be manually reset via keypad or by turning the unit off,
then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (see reset condition above). Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check CDCON2
a. Inspect condenser fan contactor coil and terminals. Verify there is no damage to coil, and no dam-
age or corrosion at terminals.
b. Check contactor coil resistance. Refer to
for correct electrical values. Cannot be
opened (infinite ohms), shorted (Zero Ohms) or shorted to ground.
c. Check amp draw of coil. Refer to
for correct electrical values. Use ammeter.
2.
Check CDCON2 Current Draw
a. Use Component Test Mode to energize CDCON2. (Refer to
.) Verify Current Draw
on Component Test Mode Screen. Refer to
for correct electrical values.
b. Check coil voltage between A1 and A2. Verify 12 VDC between A1 & A2.
c. Check resistance at contacts. Verify contacts are closed at L1
−
T1, L2
−
T2, L3
−
T3.
d. Use Component Test Mode to test actual current draw of the circuit. (Refer to
Refer to
for values. View current draw in Component Test Mode screen.
e. Inspect harness & control box connector pins & terminals. (See wiring schematic
Verify there is no physical damage to harness, and no damage, moisture, or corrosion in connec-
tors.
3.
Check PSCON1 and PSCON2
Check for loose wires or open contact. Verify there is no physical damage, and no damage, moisture,
or corrosion in connectors.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......