9–1
62-11640
SECTION 9
UNIT TROUBLESHOOTING
NOTICE
Should a problem develop with these components, contact your nearest Carrier Transicold
dealer for replacement.
NOTE
Run a Pretrip and check all active alarms before continuing with troubleshooting.
9.1
ENGINE
Indication/Trouble
Possible Causes
Action / Reference
9.1.1
Engine Will Not Start
Starter motor will not crank or low
cranking speed
Battery insufficiently charged
Battery cable connections loose or corroded
Check
Damaged or corroded electrical connections at starter
Check/Repair
Starter motor malfunction
Starter motor solenoid defective
Engine Manual
Open starting circuit
Incorrect grade of lubricating oil
High suction pressure
Internal generator damage
Internal generator damage
Generator magnetically locked, casing drag
Starter motor cranks but engine
fails to start
No fuel in tank
Check
Air in fuel system
Water in fuel system
Drain Sump &
Plugged fuel filter
Plugged inlet screen to mechanical pump.
Plugged inlet screen to electric pump.
Plugged fuel lines to injector(s)
Check
ENCU defective
Replace
Engine preheat defective
Starter cranks, engages, but dies
after a few seconds
Incorrect grade of lubricating oil
Voltage drop in battery cable(s)
Check
ENCU defective
Replace
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......