SWITCHING OPERATING STATE
WARNING
!
Do not connect power plug to any electrical outlet without checking that it meets the 460/3/60
and 30 Amp electrical requirements of the unit.
WARNING
!
Ensure the power plug is clean and dry before connecting to any electrical outlet/receptacle.
Standby Electrical Guidelines
NOTE
The unit is equipped with automatic phase reversal which insures that the electric motors will run in the
correct direction.
For safe, reliable operation in Electric Operation, it is important to consider the following guidelines:
•
NEVER
connect the unit to a high voltage power source unless the START/RUN
−
OFF switch is in OFF
position.
• The power supply cable and circuit breaker must comply with local electrical code and unit specifications.
• The power supply cable must be equipped with a ground connection.
• Repairs or maintenance to the supply voltage circuit should only be performed by licensed/authorized per-
sonnel.
OFF
START/RUN
O
I
CONTINUOUS
START/STOP
MENU
ALARM
DEFROST
COOL
DIESEL
START/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F
SETPOINT F
If DIESEL is displayed, the unit is in Engine Operation.