background image

1

337938---782---CBP

337938---784---CBP

337938---785---CBP

337938---786---CBP

337938---787---CBP

337938---790---CBP

Installation Instructions

INDUCER HOUSING KIT

FOR SINGLE---STAGE, TWO---STAGE AND

MODULATING GAS FURNACES

NOTE

: Read the entire instruction manual before starting the

installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit. Consult local
building codes, the current editions of the National Fuel Gas Code

(NFGC) NFPA 54/ANSI Z223.1 and the National Electrical Code

(NEC) NFPA 70.
In Canada, refer to the current editions of the National Standards of

Canada CAN/CSA--B149.1 and .2 Natural Gas and Propane
Installation Codes, and Canadian Electrical Code CSA C22.1.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies hazards

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

FIRE, EXPLOSION, ELECTRICAL SHOCK

HAZARD

Failure to follow this warning could result in personal injury,

death and/or property damage.
The ability to properly perform maintenance on this equipment

requires certain knowledge, mechanical skills, tools, and

equipment. If you do not possess these, do not attempt to

perform any maintenance on this equipment other than those

procedures recommended in the Owner’s Manual.

!

WARNING

FIRE, EXPLOSION, ELECTRICAL SHOCK AND

CARBON MONOXIDE POISONING HAZARD

Failure to follow instructions could result in personal injury,

death or property damage.
Improper

installation,

adjustment,

alteration,

service,

maintenance, or use can cause carbon monoxide poisoning,

explosion, fire, electrical shock, or other conditions, which

could result in personal injury or death. Consult your

distributor or branch for information or assistance. The

qualified installer or agency must use only factory--authorized

kits or accessories when servicing this product.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF position and

install a lockout tag. There may be more than one electrical

supply to the furnace. Check accessories and cooling unit for

additional electrical supplies that must be shut off during

furnace servicing. Lockout and tag switch with a suitable

warning label. Verify proper operation after servicing.

!

WARNING

INTRODUCTION

This instruction covers installation of the single--speed, two--speed,

and modulating inducer assemblies on condensing 35--in. (889

mm) tall, high--efficiency units.
The inducer should be replaced when the motor is seized, open,
shorted or grounded. The PSC motor is equipped with an internal
thermal overload. If the overload is open, allow time (several
minutes) for overload to reset.
ECM inducer motors do not have an internal overload and are in-
ternally protected through the electronics in the motor controller.
There are four (4) different PSC inducer assemblies to service all
single--stage and 2-stage furnaces with PSC inducers.
Each of the 4 PSC motors have a different horsepower and/or RPM
range required for the various size furnaces.
The motor supplied in the kit for furnaces with PSC inducers is a

2--speed inducer motor. Single--stage operation is achieved through

the use of an adapter harness included with the kit.

There is one (1) kit for modulating furnaces. The replacement

assembly may look different from the assembly installed on the

furnace, but operates the same as the original motor. The new

modulating furnace inducer kit does not require an adapter harness.

See Fig. 1.
Refer to Table 2 for the correct furnace and kit combination.

Reviews: