INTRODUCTION
11
ECMCT REFRIGERATION/ELECTRICAL DATA
Export Models (R-404A)
ECMCT-4
OHMS WATTS
AMPS
VOLTS
Def. Heater on Bottom side
72.4
582
2.7
215
of Top Coil
Control Bellows Heater below
5375
9
.04
215
Def. Controls
End Breaker Heater behind
3071.4
15
.07
215
each End Breaker
Glass Heater around
826.9
56
.26
215
Front Glass
Heated Glass Lid
41.3
14
.58
24
(each)
ECMCT-6
OHMS WATTS
AMPS
VOLTS
Def. Heater on Bottom side
51
904
4.2
215
of Top Coil
Control Bellows Heater below
5375
9
.04
215
Def. Controls
End Breaker Heater behind
3071.4
15
.07
215
each End Breaker
Glass Heater around
565.8
82
.38
215
Front Glass
Heated Glass Lid
26.1
22
.92
24
(each)
COMPRESSOR AMPERAGE
CABINET
RUN
CAP.
MODEL
MFG.
MODEL
HP
VOLTS
LRA
AMPS
OZ.
TUBE
ECMCT-4
Copeland
KAJB-010E-CAV
1
200
40
8.0
20
8' x .042
ECMCT-6
Copeland
KAJB-010E-CAV
1
200
40
8.0
25
8' x .042
Summary of Contents for 52-2038-01
Page 3: ...SECTION I Introduction...
Page 13: ...12 INTRODUCTION WIRING DIAGRAM 00 1667 00 CMCT 4 6 8...
Page 14: ...INTRODUCTION 13 WIRING DIAGRAM 00 1670 00 CMCT 10...
Page 15: ...14 INTRODUCTION WIRING DIAGRAM 00 1934 00 ECMCT 4 6 8 Export Models...
Page 16: ...INTRODUCTION 15 LAMP WIRING DETAIL Upper Raceway Typical...
Page 17: ...SECTION II Maintenance Repair...
Page 23: ...CONDENSING UNIT LAYOUT 24 MAINTENANCE REPAIR...
Page 32: ...UPPER CROSS SECTION CMCT Models...
Page 38: ...SECTION III Parts List...