background image

 

5

 

Lighting Your Furnace 

 

1. This appliance is equipped with an ignition device which

automatically lights the burner. Do NOT try to light the
burner by hand.

2. After preparing the furnace for heating operation (See pre-

vious section) and checking for oil, proceed as follows.

3. For a heating/cooling system, set the thermostat to HEAT

and the fan to AUTO. Set the thermostat to the desired
room temperature and TURN ON the electrical power to
the furnace.

4. The burner should light and the system should be controlled

by the thermostat.

 

Turning Off Your Furnace

 

Follow these simple procedures to put your furnace into retire-
ment for the summer.

1. Set the thermostat to the lowest setting.

2. TURN OFF all electric power to the appliance.

3. Turn the oil supply OFF.

4. If applicable, TURN OFF water supply to humidifier.

5. If furnace blower will be necessary for cooling system, re-

member to turn electric power back ON when needed for air
conditioning.

 

MAINTAINING YOUR UNIT

 

The life of your system depends on the care you give it. Proper
care assures good performance; lack of it can damage the unit.

Here are the things you should do, or have your dealer service
technician do for you.

 

NOTE:

 

 Before you start, TURN OFF all electrical power to

unit and turn thermostat to OFF.

 

CAUTION

 

This furnace is equipped with an interrupted type
electronic ignition system. DO NOT ATTEMPT TO
LIGHT WITH A MATCH.

 

DANGER!

 

HIGH VOLTAGE AT IGNITOR.

!

!

 

Filters

 

A filter is supplied with the furnace (except 58BGA). It is
NECESSARY THAT ALL FURNACES BE EQUIPPED
WITH A FILTER.

If a different type of filter is used, it must be an equivalent high
airflow capacity
.

 

Keeping Filters Clean

 

As a homeowner, this is your most important responsibility. A
dirty filter reduces the efficiency of your system, causes erratic
performance of controls, and could result in damage to the mo-
tor or heat exchanger.

1. Inspect filters at regular intervals depending upon dirt con-

ditions. For new homes, check filters every week for 4 con-
secutive weeks. In all cases, inspect your filters at least every
3 to 4 weeks when the system is in constant operation. Re-
place or clean filter at least at the beginning of each season
(heating & cooling) and thereafter as needed.

2.  If the permanent filter supplied with the unit becomes dirty,

it can be cleaned with cold water and soap.

Be sure that the filter is thoroughly dry before installing back
into the furnace.

 

Lubricating Motors

 

Direct drive motor and blower assemblies are factory lubri-
cated and normally do not require oiling. If oiling is required,
lubrication of the blower motor is to be performed only by a
qualified service agency.

 

WARNING

 

Never operate unit without a filter or with filter ac-
cess door removed. Failure to adhere to this warn-
ing could lead to a hazardous condition which
could lead to equipment damage and bodily harm.

yyy

yyy

!

Summary of Contents for 58BGA

Page 1: ...NUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL FIRED FURNACE NOTE TO INSTALLER THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER HEATING COOLING O I L F U R N A C E 58BGA 58BLA 58BMA 58BTA Thi d t t d ith F M k 4 0 4 ...

Page 2: ...ISE INSTALLATION DATA Date Installed Dealer Name Address City State Zip Telephone FURNACE Product No Model No Serial No 2 58BLA LOW BOY 4 58BTA UPFLOW HORIZONTAL SPLIT SYSTEM Product No Model No Serial No INDOOR COIL Product No Model No Serial No ...

Page 3: ...EACHES WAXES OR OTHER CLEANING COMPOUNDS PLASTIC OR PLAS TIC CONTAINERS GASOLINE KEROSENE CIGARETTE LIGHTER FLUID DRY CLEANING FLUIDS OR PAINTING COMPOUNDS FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration ser vice or maintenance can cause injury or property damage Re...

Page 4: ... all uncertain contact your dealer for qualified maintenance and service The electronic fan control will automatically turn on the blower after 30 sec Fan on control is not adjustable The air moved over the heat exchanger by the blower is warmed and passes through the ducts to the room registers When the thermostat is satisfied the circuit is de energized and the primary control shuts off the burn...

Page 5: ...ype electronic ignition system DO NOT ATTEMPT TO LIGHT WITH A MATCH DANGER HIGH VOLTAGE AT IGNITOR Filters A filter is supplied with the furnace except 58BGA It is NECESSARY THAT ALL FURNACES BE EQUIPPED WITH A FILTER If a different type of filter is used it must be an equivalent high airflow capacity Keeping Filters Clean As a homeowner this is your most important responsibility A dirty filter re...

Page 6: ...alled in an insulated space must be kept free and clear of insulating materials After the furnace is installed or whenever addi tional insulation is added check that all combus tion air intakes are free and clear and that all clearance dimensions are maintained INSULAT ING MATERIALS MAY BE COMBUSTIBLE WARNING Do not use this furnace if any part has been under water Immediately call a qualified ser...