background image

10

AIR DELIVERY—CFM (With Filter)*

UNIT SIZE

RETURN-AIR

SUPPLY

SPEED

EXTERNAL STATIC PRESSURE (In. wc)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

045-08

Bottom

or

Side(s)

High

Med-High

Med-Low

Low

1120

930

820

725

1075

890

785

690

1020

850

750

655

960

805

700

605

895

750

650

555

815

680

585

495

720

600

505

405

605

500

400

305

455

345

235

340

195

045-12

Bottom

or

Side(s)

High

Med-High

Medium

Med-Low

Low

1465

1295

1150

1030

860

1400

1260

1120

1008

835

1325

1210

1085

980

810

1250

1155

1040

945

780

1175

1090

985

895

745

1085

1015

920

835

700

980

930

835

765

635

860

830

740

685

555

725

700

620

070-08

Bottom

or

Side(s)

High

Med-High

Med-Low

Low

1140

915

795

690

1105

885

770

665

1055

855

740

630

1010

825

700

590

955

785

655

550

885

725

600

475

815

655

510

415

715

530

420

340

545

420

325

245

390

280

070-12

Bottom

or

Side(s)

High

Med-High

Medium

Med-Low

Low

1440

1180

1015

885

695

1400

1165

1020

885

700

1355

1150

1010

880

700

1300

1125

990

865

690

1240

1085

965

845

670

1170

1030

925

815

640

1090

970

875

770

600

1000

890

800

700

540

890

785

700

605

460

745

645

560

475

345

070-16

Bottom

or

Side(s)

High

Med-High

Medium

Med-Low

Low

1840

1610

1460

1260

1065

1790

1575

1430

1240

1040

1730

1535

1400

1215

1015

1670

1485

1360

1180

985

1605

1435

1315

1145

955

1530

1370

1260

1100

915

1450

1305

1205

1040

875

1370

1230

1130

985

825

1275

1145

1055

915

765

1170

1055

965

835

695

090-14

Bottom

or

Side(s)

High

Med-High

Med-Low

Low

1650

1515

1385

1205

1600

1485

1360

1180

1535

1440

1320

1160

1465

1380

1260

1120

1385

1300

1195

1065

1285

1220

1120

1005

1175

1115

1025

925

1055

990

915

810

895

830

710

630

645

600

565

510

090-16

Bottom

or

Side(s)

High

Med-High

Medium

Med-Low

Low

2060

1710

1470

1260

1030

2000

1695

1475

1265

1025

1930

1665

1450

1245

1020

1835

1585

1390

1225

990

1755

1480

1335

1165

940

1620

1390

1230

1090

890

1490

1245

1120

995

810

1315

1110

1005

880

720

1115

955

855

750

615

910

775

690

600

500

090-20

Bottom

Only

High

Med-High

Medium

Med-Low

Low

2380

2185

1905

1595

1340

2295

2115

1865

1565

1310

2205

2045

1815

1530

1280

2105

1960

1740

1485

1225

2005

1875

1670

1430

1170

1900

1770

1590

1355

1120

1775

1655

1490

1275

1040

1650

1535

1390

1160

955

1510

1400

1245

1055

850

1335

1240

1110

920

750

Both Sides

or 1

Side & Bottom

High

Med-High

Medium

Med-Low

Low

2485

2175

1845

1540

1280

2415

2130

1815

1515

1250

2330

2070

1770

1475

1220

2230

2000

1720

1435

1190

2135

1930

1655

1385

1155

2030

1840

1580

1335

1105

1920

1740

1500

1270

1035

1790

1620

1395

1175

945

1645

1495

1270

1045

845

1485

1345

1090

915

745

1 Side Only

High

Med-High

Medium

Med-Low

Low

2420

2160

1850

1530

1290

2345

2110

1815

1490

1250

2265

2045

1765

1455

1220

2165

1960

1710

1420

1190

2070

1885

1635

1375

1155

1960

1790

1560

1320

1110

1850

1695

1480

1250

1040

17720

1570

1380

1160

950

1570

1445

1250

1055

835

1420

1305

1110

905

740

* A filter is required for each return---air supply. Airflow performance includes 3/4---in. (19 mm) washable filter media such as contained in factory---authorized

accessory filter rack. To determine airflow performance without this filter, assume an additional .1 available external static pressure.

— Indicates unstable operating conditions.

58C

TA

/C

TX

Summary of Contents for 58CTA/CTX

Page 1: ...ology Intelligent microprocessor control S Two stage heating with single stage thermostat with patented Adaptive Control Technology S Very low operating sound through low stage operation and QuieTecht system SmartEvapt Humidity control when using a Thermidistatt Infinityt control Comfort Fant adjustable constant fan speed from the thermostat S High Efficiency Media Filtration Cabinet included S Mi...

Page 2: ...00 Btuh 08 800 CFf7 12 1200 CFM 14 1400 CFM 16 1600 CFM Input Capacity 20 2000 CFM 045 44 000 Btuh 110 110 000 Btuh 22 2200 CFM 070 66 000 Btuh 135 132 000 Btuh 090 88 000 Btuh 155 154 000 Btuh Series Number EFFICIENCY RATING CERTIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS Before purchasing this appliance read important energy cost and efficiency information available from ...

Page 3: ...TCH BLOWER AND MOTOR RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH FLAME SENSOR Elbow may be turned to a different position depending on type of installation A04138 NOTE The 58CTA CTX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion ...

Page 4: ... C Auto Changeover TP NAC TC NAC For use with 1 speed Heat Pump deg F C Auto Changeover TP NHP TC NHP For use with 2 speed Air Conditioner deg F C Auto Changeover TP NRH For use with multi use stage configurations deg F C Auto Changeover Temperature and Humidity control TP PRH THERMOSTAT PROGRAMMABLE For use with 1 speed Air Conditioner deg F C Auto Changeover 7 Day Programmable TP PAC For use wit...

Page 5: ...2UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X X X X X KGACA02015FC X X X Natural to Propane Conversion Kit KGANP4601ALL X X X X...

Page 6: ...75 1195 1265 1030 1580 1325 Cooling 895 1175 955 1240 1605 1385 1755 2005 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 2 2 3 3 3 4 4 4 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certi...

Page 7: ...2230 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 5 5 5 6 6 7 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M r...

Page 8: ...installations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit KGAVG0101DFG required in downflow installations with bottom vent configuration 7 ...

Page 9: ... 8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02066 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02067 58CTA CTX ...

Page 10: ... 1320 1160 1465 1380 1260 1120 1385 1300 1195 1065 1285 1220 1120 1005 1175 1115 1025 925 1055 990 915 810 895 830 710 630 645 600 565 510 090 16 Bottom or Side s High Med High Medium Med Low Low 2060 1710 1470 1260 1030 2000 1695 1475 1265 1025 1930 1665 1450 1245 1020 1835 1585 1390 1225 990 1755 1480 1335 1165 940 1620 1390 1230 1090 890 1490 1245 1120 995 810 1315 1110 1005 880 720 1115 955 85...

Page 11: ...05 1500 1295 1835 1640 1450 1265 1710 1550 1380 1210 1590 1465 1315 1150 1470 1360 1215 995 1335 1210 1005 865 1025 945 855 745 835 785 670 540 135 22 Bottom Only High Med High Med Low Low 2485 2195 1880 1640 2400 2150 1850 1635 2310 2090 1820 1615 2215 2000 1780 1585 2110 1920 1715 1530 2000 1825 1635 1465 1880 1720 1540 1370 1725 1565 1415 1255 1535 1405 1290 1150 1355 1255 1160 1040 Both Sides ...

Page 12: ...e use of both side inlets a combination of 1 side and the bottom or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM FURNACE SIZE A CABINET WIDTH IN mm D SUPPLY AIR WIDTH IN mm E RETURN AIR WIDTH IN mm F CENTER LINE TOP AND BOTTOM FLUE COLLAR IN mm FLUE COLLAR IN mm SHIP WT LB KG FILTER MEDIA CABINET IN mm 045 08 14 3 16 360 12 9 16 319 12 11 16 322 ...

Page 13: ...7 432 16 1 4 413 15 381 20 508 mm 21 533 20 1 4 514 19 483 24 610 mm 25 635 24 1 4 616 23 584 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 1 2 With Flanges Bent Out 23 1 8 Opening 5 3 4 C Opening with Flanges Bent In B 600 mm 594 mm 603 mm 146 mm 651 mm 622 mm 587 mm A00444 58CTA CTX 58CTA CTX ...

Page 14: ...14 A08471 58CTA CTX ...

Page 15: ... 2 15 14 090 14 115 60 1 127 104 8 2 34 10 3 15 14 090 16 115 60 1 127 104 9 9 28 8 5 15 14 090 20 115 60 1 127 104 12 9 34 10 3 20 12 110 12 115 60 1 127 104 8 2 34 10 3 15 14 110 16 115 60 1 127 104 10 1 28 8 5 15 14 110 22 115 60 1 127 104 13 7 32 9 7 20 12 135 16 115 60 1 127 104 10 2 27 8 2 15 14 135 22 115 60 1 127 104 14 5 30 9 1 20 12 155 20 115 60 1 127 104 15 0 29 8 8 20 12 Permissible l...

Page 16: ...f 030 in 76 mm thickness minimum pre painted galvanized steel Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe Heat Exchangers Heat exchangers shall be a 4 Pa...

Reviews: