6
PHYSICAL DATA
UNIT SIZE
045
070
090
08
12
08
12
16
14
16
20
OUTPUT CAPACITY
BTUH*
(Nonweatherized
ICS) †
All 58CTA; 58CTX
Upflow
High
35,000
36,000
54,000
54,000
53,000
71,000
71,000
71,000
Low
23,000
23,000
36,000
36,000
35,000
47,000
47,000
47,000
All 58CTX Downflow/
Horizontal
High
34,000
34,000
51,000
51,000
51,000
68,000
68,000
68,000
Low
23,000
23,000
36,000
36,000
35,000
47,000
47,000
47,000
INPUT BTUH*
All 58CTA; 58CTX
Upflow
High
44,000
44,000
66,000
66,000
66,000
88,000
88,000
88,000
Low
29,000
29,000
43,500
43,500
43,500
58,000
58,000
58,000
All 58CTX Downflow/
Horizontal
HIgh
42,000
42,000
63,000
63,000
63,000
84,000
84,000
84,000
Low
29,000
29,000
43,500
43,500
43,500
58,000
58,000
58,000
AFUE † *
Nonweatherized ICS
80.0
80.0
80.0
80.0
80.0
80.0
80.0
80.0
SHIPPING WEIGHT --- LB (KG)
116 (53)
119 (54)
120 (54)
124 (56)
138 (63)
136 (62)
151 (68)
156 (71)
CERTIFIED TEMP RISE RANGE --- ° F (° C)
High
30---60
(17---33)
20---50
(11---28)
40---70
(22---39)
30---60
(17---33)
25---55
(14---30)
40---70
(22---39)
30---60
(17---33)
25---55
(14---30)
Low
20---50
(11---28)
15---45
(8---25)
30---60
(17---33)
30---60
(17---33)
15---45
(8---25)
25---55
(14---30)
25---55
(14---30)
15---45
(8---25)
CERTIFIED EXT
STATIC PRESSURE
Heating
0.10
0.10
0.12
0.12
0.12
0.15
0.15
0.15
Cooling
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
AIRFLOW CFM‡
Heating High/Low
820/725
1030/860
790/685
885/695
1570/1045 1375/1195 1265/1030
1580/1325
Cooling
895
1175
955
1240
1605
1385
1755
2005
LIMIT CONTROL
SPST
HEATING BLOWER CONTROL
Solid-State Time Operation
BURNERS (Monoport)
2
2
3
3
3
4
4
4
GAS CONNECTION SIZE
1/2---in. NPT
GAS VALVE (Redundant) Manufacturer
White-Rodgers
Minimum Inlet Pressure (In. wc)
4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc)
13.6 (Natural Gas)
IGNITION DEVICE
Hot Surface
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305 M)
above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions. In Canada, derate the unit
10 percent for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return-air supply.
ICS — Isolated Combustion System
BLOWER PERFORMANCE DATA
UNIT SIZE
045
070
090
08
12
08
12
16
14
16
20
DIRECT-DRIVE MOTOR Hp (PSC)
1/5
1/3
1/5
1/3
1/2
1/3
1/2
3/4
MOTOR FULL LOAD AMPS
2.8
5.1
2.8
5.1
7.4
5.2
7.4
11.0
RPM (Nominal) – Speeds
1075-4
1075-5
1075-4
1075-5
1075-5
1075-4
1075-5
1075-5
BLOWER WHEEL DIAMETER × WIDTHS ---
In. (mm)
10 x 6
(254 x
152)
10 x 6
(254 x
152)
10 x 6
(254 x
152)
10 x 6
(254 x
152)
11 x 8
(279 x
203)
10 x 8
(254 x
203)
10 x 10
(254 x
254)
11 x 11
(279 x
279)
PSC---Permanent Split Capacitor
58C
TA
/C
TX