PHYSICAL DATA

UNIT SIZE

045

070

090

08

12

08

12

16

14

16

20

OUTPUT CAPACITY

BTUH*

(Nonweatherized

ICS) †

All 58CTA; 58CTX

Upflow

High

35,000

36,000

54,000

54,000

53,000

71,000

71,000

71,000

Low

23,000

23,000

36,000

36,000

35,000

47,000

47,000

47,000

All 58CTX Downflow/

Horizontal

High

34,000

34,000

51,000

51,000

51,000

68,000

68,000

68,000

Low

23,000

23,000

36,000

36,000

35,000

47,000

47,000

47,000

INPUT BTUH*

All 58CTA; 58CTX

Upflow

High

44,000

44,000

66,000

66,000

66,000

88,000

88,000

88,000

Low

29,000

29,000

43,500

43,500

43,500

58,000

58,000

58,000

All 58CTX Downflow/

Horizontal

HIgh

42,000

42,000

63,000

63,000

63,000

84,000

84,000

84,000

Low

29,000

29,000

43,500

43,500

43,500

58,000

58,000

58,000

AFUE † *

Nonweatherized ICS

80.0

80.0

80.0

80.0

80.0

80.0

80.0

80.0

SHIPPING WEIGHT --- LB (KG)

116 (53)

119 (54)

120 (54)

124 (56)

138 (63)

136 (62)

151 (68)

156 (71)

CERTIFIED TEMP RISE RANGE --- ° F (° C)

High

30---60

(17---33)

20---50

(11---28)

40---70

(22---39)

30---60

(17---33)

25---55

(14---30)

40---70

(22---39)

30---60

(17---33)

25---55

(14---30)

Low

20---50

(11---28)

15---45

(8---25)

30---60

(17---33)

30---60

(17---33)

15---45

(8---25)

25---55

(14---30)

25---55

(14---30)

15---45

(8---25)

CERTIFIED EXT

STATIC PRESSURE

Heating

0.10

0.10

0.12

0.12

0.12

0.15

0.15

0.15

Cooling

0.50

0.50

0.50

0.50

0.50

0.50

0.50

0.50

AIRFLOW CFM‡

Heating High/Low

820/725

1030/860

790/685

885/695

1570/1045 1375/1195 1265/1030

1580/1325

Cooling

895

1175

955

1240

1605

1385

1755

2005

LIMIT CONTROL

SPST

HEATING BLOWER CONTROL

Solid-State Time Operation

BURNERS (Monoport)

2

2

3

3

3

4

4

4

GAS CONNECTION SIZE

1/2---in. NPT

GAS VALVE (Redundant) Manufacturer

White-Rodgers

Minimum Inlet Pressure (In. wc)

4.5 (Natural Gas)

Maximum Inlet Pressure (In. wc)

13.6 (Natural Gas)

IGNITION DEVICE

Hot Surface

* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305 M)

above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions. In Canada, derate the unit

10 percent for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level.

† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each

return-air supply.

ICS — Isolated Combustion System

BLOWER PERFORMANCE DATA

UNIT SIZE

045

070

090

08

12

08

12

16

14

16

20

DIRECT-DRIVE MOTOR Hp (PSC)

1/5

1/3

1/5

1/3

1/2

1/3

1/2

3/4

MOTOR FULL LOAD AMPS

2.8

5.1

2.8

5.1

7.4

5.2

7.4

11.0

RPM (Nominal) – Speeds

1075-4

1075-5

1075-4

1075-5

1075-5

1075-4

1075-5

1075-5

BLOWER WHEEL DIAMETER × WIDTHS ---

In. (mm)

10 x 6

(254 x

152)

10 x 6

(254 x

152)

10 x 6

(254 x

152)

10 x 6

(254 x

152)

11 x 8

(279 x

203)

10 x 8

(254 x

203)

10 x 10

(254 x

254)

11 x 11

(279 x

279)

PSC---Permanent Split Capacitor

58C

TA

/C

TX

Summary of Contents for 58CTA/CTX

Page 1: ...ology Intelligent microprocessor control S Two stage heating with single stage thermostat with patented Adaptive Control Technology S Very low operating sound through low stage operation and QuieTecht system SmartEvapt Humidity control when using a Thermidistatt Infinityt control Comfort Fant adjustable constant fan speed from the thermostat S High Efficiency Media Filtration Cabinet included S Mi...

Page 2: ...00 Btuh 08 800 CFf7 12 1200 CFM 14 1400 CFM 16 1600 CFM Input Capacity 20 2000 CFM 045 44 000 Btuh 110 110 000 Btuh 22 2200 CFM 070 66 000 Btuh 135 132 000 Btuh 090 88 000 Btuh 155 154 000 Btuh Series Number EFFICIENCY RATING CERTIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS Before purchasing this appliance read important energy cost and efficiency information available from ...

Page 3: ...TCH BLOWER AND MOTOR RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS MANIFOLD GAS BURNER BLOWER DOOR SAFETY SWITCH FLAME SENSOR Elbow may be turned to a different position depending on type of installation A04138 NOTE The 58CTA CTX Furnaces are factory shipped for use with natural gas These furnaces can be field converted for propane gas with a factory authorized and listed accessory conversion ...

Page 4: ... C Auto Changeover TP NAC TC NAC For use with 1 speed Heat Pump deg F C Auto Changeover TP NHP TC NHP For use with 2 speed Air Conditioner deg F C Auto Changeover TP NRH For use with multi use stage configurations deg F C Auto Changeover Temperature and Humidity control TP PRH THERMOSTAT PROGRAMMABLE For use with 1 speed Air Conditioner deg F C Auto Changeover 7 Day Programmable TP PAC For use wit...

Page 5: ...2UPH X X X X X X X X X X X X X X Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X Downflow Vent Guard KGAVG0101DFG X X X X X X X X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X Chimney Adapter Kit KGACA02014FC X X X X X X X X X X X KGACA02015FC X X X Natural to Propane Conversion Kit KGANP4601ALL X X X X...

Page 6: ...75 1195 1265 1030 1580 1325 Cooling 895 1175 955 1240 1605 1385 1755 2005 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 2 2 3 3 3 4 4 4 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certi...

Page 7: ...2230 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid State Time Operation BURNERS Monoport 5 5 5 6 6 7 GAS CONNECTION SIZE 1 2 in NPT GAS VALVE Redundant Manufacturer White Rodgers Minimum Inlet Pressure In wc 4 5 Natural Gas Maximum Inlet Pressure In wc 13 6 Natural Gas IGNITION DEVICE Hot Surface Gas input ratings are certified for elevations to 2000 ft 610 M For elevations above 2000 ft 610 M r...

Page 8: ...installations must use Type B vent immediately after exiting the furnace except when KGAVG0101DFG is used in downflow position 4 Type B vent where required refer to Note 1 5 4 in 102 mm single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit 6 Accessory Downflow Vent Guard Kit KGAVG0101DFG required in downflow installations with bottom vent configuration 7 ...

Page 9: ... 8 9 HORIZONTAL RIGHT A02070 SEE NOTES 1 2 4 7 8 9 HORIZONTAL RIGHT A02069 SEE NOTES 1 2 4 7 8 9 HORIZONTAL LEFT A02064 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02065 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02066 SEE NOTES 1 2 4 5 7 8 9 HORIZONTAL LEFT A02067 58CTA CTX ...

Page 10: ... 1320 1160 1465 1380 1260 1120 1385 1300 1195 1065 1285 1220 1120 1005 1175 1115 1025 925 1055 990 915 810 895 830 710 630 645 600 565 510 090 16 Bottom or Side s High Med High Medium Med Low Low 2060 1710 1470 1260 1030 2000 1695 1475 1265 1025 1930 1665 1450 1245 1020 1835 1585 1390 1225 990 1755 1480 1335 1165 940 1620 1390 1230 1090 890 1490 1245 1120 995 810 1315 1110 1005 880 720 1115 955 85...

Page 11: ...05 1500 1295 1835 1640 1450 1265 1710 1550 1380 1210 1590 1465 1315 1150 1470 1360 1215 995 1335 1210 1005 865 1025 945 855 745 835 785 670 540 135 22 Bottom Only High Med High Med Low Low 2485 2195 1880 1640 2400 2150 1850 1635 2310 2090 1820 1615 2215 2000 1780 1585 2110 1920 1715 1530 2000 1825 1635 1465 1880 1720 1540 1370 1725 1565 1415 1255 1535 1405 1290 1150 1355 1255 1160 1040 Both Sides ...

Page 12: ...e use of both side inlets a combination of 1 side and the bottom or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM FURNACE SIZE A CABINET WIDTH IN mm D SUPPLY AIR WIDTH IN mm E RETURN AIR WIDTH IN mm F CENTER LINE TOP AND BOTTOM FLUE COLLAR IN mm FLUE COLLAR IN mm SHIP WT LB KG FILTER MEDIA CABINET IN mm 045 08 14 3 16 360 12 9 16 319 12 11 16 322 ...

Page 13: ...7 432 16 1 4 413 15 381 20 508 mm 21 533 20 1 4 514 19 483 24 610 mm 25 635 24 1 4 616 23 584 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 1 2 With Flanges Bent Out 23 1 8 Opening 5 3 4 C Opening with Flanges Bent In B 600 mm 594 mm 603 mm 146 mm 651 mm 622 mm 587 mm A00444 58CTA CTX 58CTA CTX ...

Page 14: ...14 A08471 58CTA CTX ...

Page 15: ... 2 15 14 090 14 115 60 1 127 104 8 2 34 10 3 15 14 090 16 115 60 1 127 104 9 9 28 8 5 15 14 090 20 115 60 1 127 104 12 9 34 10 3 20 12 110 12 115 60 1 127 104 8 2 34 10 3 15 14 110 16 115 60 1 127 104 10 1 28 8 5 15 14 110 22 115 60 1 127 104 13 7 32 9 7 20 12 135 16 115 60 1 127 104 10 2 27 8 2 15 14 135 22 115 60 1 127 104 14 5 30 9 1 20 12 155 20 115 60 1 127 104 15 0 29 8 8 20 12 Permissible l...

Page 16: ...f 030 in 76 mm thickness minimum pre painted galvanized steel Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounted to reduce vibration transmission Draft Safeguard Switch Draft Safeguard Switch blocked vent safeguard shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe Heat Exchangers Heat exchangers shall be a 4 Pa...

Reviews: