Fig.
9
—
Furnace
Staging
Algorithm
A03090
Using recor
ded Lo
w Heat (LH)
and High Heat (HH) v
alues,
calculate the Heat Load (HL)
using:
HL=(228 X LH) + (350 X HH)
Is HL < 3648?
Is HL > 5600?
Calculated Lo
w Heat (LH) on
time will be 16 min
utes
Calculated Lo
w Heat (LH) on
time will be 0 min
utes
Ye
s
Ye
s
Unit will initiate the ne
xt c
y
c
le
in Lo
w Heat to the nearest
min
ute f
or a period of time as
calculated b
y
the f
ollo
wing:
LH
run time
= (5600-HL)/122
Unit will initiate the ne
xt c
y
c
le in
Lo
w Heat f
or a maxim
um of 16
min
utes bef
ore initiating High Heat
if the call f
or heat still e
xists
Unit will initiate the ne
xt c
y
c
le in
High Heat until the
thermostat is satisfied.
The ne
xt c
y
c
le will be initiated
with the calculated Lo
w Fire run
time bef
ore initiating High Heat if
a call f
or heat is still present
The Lo
w Heat and High Heat
run times f
or this c
y
c
le will be
as calculated
Thermostat is satisfied.
42