59CU5A: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
13
Table 5 – Condensate Trap Configurations
Upflow installations utilizing the right side air return o
INSTALLATION
Preparing the Furnace – Before Setting in Place
1. Remove appropriate knockout based off the installation orientation.
L12F019B
Fig. 12 – Knockout Removal
2. Remove two of the factory-installed drain plugs from collector box.
Orientation specific drain plugs, see
.
3. Check that all pre-installed gaskets on trap components are present,
adhered, and undamaged.
A200075
Fig. 13 – Drain Plugs
A200076
Fig. 14 – Upflow Example of Trap Adapter Installation
A200064
Fig. 15 – Upflow Condensate Drain
Part
Installation Configuration
Horizontal
Upflow
Upflow
Offset
Required
Required
Required
Not
Required
Required
Required
Not
Required
Required
Required
Not
Required
Not
Required
Required
(accessory kit
purchased
separately)
NOTICE
!
Upflow installation utlilizing the right side air return opening should
follow the Upflow Specific Steps - Offset Installation to ensure the full
opening is available for return ductwork
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear
appropriate protective clothing, safety glasses and gloves when
handling parts, and servicing furnaces.
Main Trap
A200090
Adapter
A200091
Plate
A200092
Offset Adapter
A200093
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in property damage, personal
injury or death.
Missing or damaged gaskets on trap components may result in flue gas
leakage and water leakage.
Remove these for Horizontal Left
Remove these for Horizontal Right
Remove these for Upflow