59SP6A: Installation, Start-up, Operating, Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
26
NOTE:
1.Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW4-3 set to OFF.
Set both SW1-5 ON for nominal 400 CFM/ton (+15% airflow).
Set SW4-3 to ON for nominal 325 CFM/ton (-7%).
Set SW1-5 to OFF and SW4-3 to ON for nominal 370 CFM/ton (+7% airflow)
The above adjustments in airflow are subject to motor horsepower range/capacity
This applies to Cooling and Low-Cooling airflow, but does not affect continuous fan airflow.
2.Maximum cooling airflow is achieved when switches SW2-6, SW2-7, SW2-8 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3.All heating CFM’s are when comfort/efficiency adjustment switch SW1-4 is set to OFF.
4.Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because high-heat operation will be
above 1.0 ESP.
5.All airflows on 21” (533 mm) casing size furnaces are 5% less on side-return only installations.
6.Side returns for 24.5” (622 mm) casing sizes require two sides, or a side and bottom to allow sufficient airflow at the return of the furnace.
7.Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return or excessive watt draw may result. A minimum filter size of 20x25” (508 x 635 mm) is required.
(SW1-5 and SW4-3 set to OFF, except as indicated. See Notes 1 and 2.)
Unit Size:
100V21--20
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
2015
1975
1935
1895
1855
1820
1785
1745
1705
1655
Cooling
(SW2-8,7,6)
OFF
OFF
ON
840
760
675
See Note 4
OFF
ON
OFF
1065
1000
935
865
See Note 4
OFF
ON
ON
1250
1190
1135
1075
1015
See Note 4
ON
OFF
OFF
1435
1380
1330
1280
1230
1175
See Note 4
ON
OFF
ON
1640
1590
1545
1500
1455
1410
1365
1320
See Note 4
ON
ON
OFF
2015
1975
1935
1895
1855
1820
1785
1745
1705
1655
ON
ON
ON
2220
2180
2145
2105
2070
2035
1995
1900
1790
1665
Maximum Clg Airflow
2
2360
2320
2265
2215
2160
2100
2005
1905
1790
1665
CF Switches
SW2-5
SW2-4
SW2-3
Low-Clg Default:
OFF
OFF
OFF
840
760
675
See Note 4
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
700
605
See Note 4
OFF
ON
OFF
840
760
675
See Note 4
OFF
ON
ON
1065
1000
935
865
See Note 4
ON
OFF
OFF
1250
1190
1135
1075
1015
See Note 4
ON
OFF
ON
1435
1380
1330
1280
1230
1175
See Note 4
ON
ON
OFF
1640
1590
1545
1500
1455
1410
1365
1320
See Note 4
ON
ON
ON
2015
1975
1935
1895
1855
1820
1785
1745
1705
1655
Cont. Fan Default:
OFF
OFF
OFF
840
760
675
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
700
605
See Note 4
OFF
ON
OFF
840
760
675
See Note 4
OFF
ON
ON
1065
1000
935
865
See Note 4
ON
OFF
OFF
1065
1000
935
865
See Note 4
ON
OFF
ON
1065
1000
935
865
See Note 4
ON
ON
OFF
1065
1000
935
865
See Note 4
ON
ON
ON
1065
1000
935
865
See Note 4
Heating (SW1)
Heat Airflow
3
1855
1810
1765
1720
1680
1640
1595
1555
1515
1470
Unit Size:
120V24--22
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
2025
1975
1925
1875
1830
1780
1730
1675
1630
1585
Cooling
(SW2-8,7,6)
OFF
OFF
ON
920
830
See Note 4
OFF
ON
OFF
1125
1050
970
890
See Note 4
OFF
ON
ON
1275
1205
1130
1060
995
See Note 4
ON
OFF
OFF
1470
1410
1345
1280
1220
1160
See Note 4
ON
OFF
ON
1670
1610
1555
1500
1440
1380
1330
See Note 4
ON
ON
OFF
2025
1975
1925
1875
1830
1780
1730
1675
See Note 4
ON
ON
ON
2255
2210
2160
2120
2075
2030
1985
1940
1825
1685
Maximum Clg Airflow
2
2455
2410
2370
2315
2250
2190
2115
1985
1830
1685
CF Switches
SW2-5
SW2-4
SW2-3
Low-Clg Default:
OFF
OFF
OFF
920
830
See Note 4
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
770
665
See Note 4
OFF
ON
OFF
920
830
See Note 4
OFF
ON
ON
1125
1050
970
890
See Note 4
ON
OFF
OFF
1275
1205
1130
1060
995
See Note 4
ON
OFF
ON
1470
1410
1345
1280
1220
1160
See Note 4
ON
ON
OFF
1670
1610
1555
1500
1440
1380
1330
See Note 4
ON
ON
ON
2025
1975
1925
1875
1830
1780
1730
1675
See Note 4
Cont. Fan Default:
OFF
OFF
OFF
920
830
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
770
665
See Note 4
OFF
ON
OFF
920
830
See Note 4
OFF
ON
ON
1125
1050
970
890
See Note 4
ON
OFF
OFF
1125
1050
970
890
See Note 4
ON
OFF
ON
1125
1050
970
890
See Note 4
ON
ON
OFF
1125
1050
970
890
See Note 4
ON
ON
ON
1125
1050
970
890
See Note 4
Heating (SW1)
Heat Airflow
3
2085
2035
1985
1940
1890
1845
1795
1750
1700
1660
Table 9 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
with Filter)