Table 3-1. Controller Configuration Variables
CONFIGURATION
NUMBER
TITLE
DEFAULT
OPTION
1
Bypass Valve Enable
In
Out
2
Evaporator Fan Speed
dS (Dual)
SS (Single)
3
Number of Sensor Probes
FoUR
dUAL
4
Dehumidification Mode
On
Off
5
Probe Calibration
noCal
CAL
6
Condenser Fan Speed Select
Off (Single)
On (Variable)
7
Unit Selection, 20FT/ 40FT/45FT
40ft
20ft,45
8
Single Phase/Three Phase Motor
1Ph
3Ph
9
Refrigerant Selection
r134a
r12, r22, bLEnd
10
Compressor Speed
Out (Single)
In (Dual)
11
Defrost “Off” Selection
noOFF
OFF
12
TXV/Solenoid Quench Valve
Out (TXV)
In (Solenoid)
13
Unloader
Out
In
14
Condenser Pressure Control (CPC)
In
Out
15
Discharge Temperature Sensor
Out
In
16
DataCORDER Option
On (Yes)
Off (No)
17
Discharge Pressure Sensor
Out (No)
In (Yes)
18
Heater
Old (Low Watt)
nEW (High Watt)
19
Controlled Atmosphere
Out (No)
In (Yes)
20
Pressure Sensor (Suction)
Out (No)
In (Yes)
21
Auto-Transformer
Std
--
22
Economy Mode Option
Off
Std, Full
23
Defrost Interval Timer Save Option
noSAV
SAV
24
Advanced Pre-Trip Enhanced Test
Off
On
25
Pre-Trip Test Points/Results Recording
rSLts
data
26
Heat Lockout
Set to --10
_
C
Set to--5
_
C
27
Suction Temperature Display
Out
In
28
Bulb Mode
Nor
bulb
29
Arctic Mode
Out
In
30
Compressor Size
41 CFM
37 CFM
31
Probe Check Logic
Std
SPEC
32
Single Evaporator Fan Option
2EF0
1EF0
33
Snap Freeze Option
Off
SnAP
34
Degree Celsius Lockout Option
bOth
_
F
35
Humidification Mode
Off
On
36
Modulation Valve Type
1
2, 3
37
Electronic Partlow
rEtur
SuPPL, bOth
38
Quench Bypass Valve
Out
In
39
Current Limit Range
Out
In
40
Demand Defrost
Out
In