T-354
2–2
2.3.8
Interrogator
Units that use the DataCORDER function are fitted with interrogator receptacles for connection of equipment to
download the recorded data. Two receptacles may be fitted; one accessible from the front of the container and the
other mounted inside the container (with the USDA receptacles).
2.3.9
Remote Monitoring
The unit may be fitted with a remote monitoring receptacle. This item allows connection of remote indicators for
COOL, DEFROST, and IN RANGE. Unless otherwise indicated, the receptacle is mounted at the control box location.
2.3.10
Communications
The unit may be fitted with a communications interface module. The communications interface module is a slave
module, which allows communication with a master central monitoring station. The module will respond to commu-
nication and return information over the main power line. Refer to the ship master system technical manual for fur-
ther information.
2.3.11
Compressor
The unit is fitted with a single speed reciprocating compressor.
2.3.12
Condenser Coil
The unit is fitted with a 3-row coil using 7mm tubing.
2.3.13
Autotransformer
An autotransformer may be provided to allow operation on 190/230, 3-phase, 50/60 hertz power. The autotrans-
former raises the supply voltage to the nominal 380/460 volt power required by the base unit. The autotransformer
may also be fitted with an individual circuit breaker for the 230 volt power.
If the unit is equipped with an autotransformer and the Low Data Rate Communications Interface Module, the auto-
transformer will be fitted with a transformer bridge unit (TBU) to assist in communications.
2.3.14
Temperature Recorder
The unit may be fitted with an electronic temperature recording device.
2.3.15
Gutters
Rain gutters may be fitted over the control box and recorder section to divert rain away form the controls. The dif-
ferent gutters include standard length bolted gutters, extended length gutters, and riveted gutters.
2.3.16
Handles
The unit may be equipped with handles to facilitate access to stacked containers. These handles may include fixed
handles (located at the sides of the unit) and/or a hinged handle at the center (attached to the condenser coil cover).
2.3.17
Thermometer Port
The unit may be fitted with ports in the front of the frame for insertion of a thermometer to measure supply and/or
return air temperature. If fitted, the port(s) will require a cap and chain.
2.3.18
Water Cooling
The refrigeration system may be fitted with a water-cooled condenser. The condenser is constructed using copper-
nickel tube for seawater applications. The water-cooled condenser is in series with the air-cooled condenser and
replaces the standard unit receiver. When operating on the water-cooled condenser, the condenser fan can be deac-
tivated by either a water pressure switch or condenser fan switch. Depending on the unit's configuration and the com-
pressor discharge temperature, the condenser fan may also be activated during water-cooled condenser operation.
2.3.19
Back Panels
Back panel designs that may be fitted include panels of aluminum and stainless steel. Panels may have access
doors and/or hinge mounting.
Summary of Contents for 69NT40-541-306
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 142: ...T 354 8 2 Figure 8 2 Schematic Diagram Standard Unit Configuration BASED ON 62 66686 00 ...
Page 148: ...T 354 8 8 ...
Page 152: ......
Page 153: ......