2–3
T-354
2.3.20
460 Volt Cable
Various power cable and plug designs are available for the main 460 volt supply. The plug options tailor the cables
to each customer's requirements.
2.3.21
230 Volt Cable
Units equipped with an autotransformer require an additional power cable for connection to the 230 volt source. Vari-
ous power cable and plug designs are available. The plug options tailor the cables to each customer's requirements.
2.3.22
Cable Restraint
Various designs are available for storage of the power cables. These options are variations of the compressor sec-
tion front cover.
2.3.23
Upper Air (Fresh Air Make Up)
The unit may be fitted with an upper fresh air makeup assembly. The fresh air makeup assembly is available with a
vent positioning sensor (VPS) and may also be fitted with screens.
2.3.24
Lower Air (Fresh Air Make Up)
The unit may be fitted with a lower fresh air makeup assembly. The fresh air makeup assembly is available with a
vent positioning sensor (VPS) and may also be fitted with screens.
2.3.25
Arctic Mode
To improve operation in cold ambients, the unit may be fitted with a crankcase heater. The crankcase heater is
operated any time the unit is under power and the compressor is not running. The purpose of the heater is to warm
the compressor oil and boil off any liquid refrigerant that may be present in the crankcase.
2.3.26
Power Correction
The unit may be fitted with a set of power factor correction capacitors to assist in correction of imbalance in current
draw by the compressor.
2.3.27
Evaporator
The evaporator section is equipped with a hermetic thermal expansion valve and a heat exchanger. The unit may
have six heaters.
2.3.28
Evaporator Fan Operation
Two evaporator fan motor operation systems are available. On units with Normal Evaporator Fan Operation, open-
ing of an evaporator fan internal protector will shut down the unit. On units equipped with single evaporator fan
capability, additional relays are installed to allow the unit to continue to operate on a single fan.
2.3.29
Labels
Operating instruction and function code listing labels will differ depending on the options installed. For example,
additional operating instructions are required to describe start-up of a unit equipped with an autotransformer.
Where the labels are available with additional languages, they are listed in the parts list.
2.3.30
Plate Set
Each unit is equipped with a tethered set of wiring schematic and wiring diagram plates. The plate sets are ordered
using a seven-digit base part number and a two-digit dash number.
2.3.31
Controller
Two different controllers are available:
1. Re-manufactured - Controller is equivalent of a new OEM controller and is supplied with a 12 month warranty.
2. Repaired - Controller has had previous faults repaired and upgraded with the latest software.
Summary of Contents for 69NT40-541-306
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ......
Page 142: ...T 354 8 2 Figure 8 2 Schematic Diagram Standard Unit Configuration BASED ON 62 66686 00 ...
Page 148: ...T 354 8 8 ...
Page 152: ......
Page 153: ......