4–3
T-354
4.1.2
Display Module
The display module (
) consists of two five digit displays and seven indicator lights.
The indicator lights include:
1.
COOL - White or Blue LED
: Energized when the refrigerant compressor is energized.
2.
HEAT - Orange LED
: Energized to indicate heater operation in heat mode, defrost mode, or dehumidification.
3.
DEFROST - Orange LED
: Energized when the unit is in defrost mode.
4.
IN RANGE - Green LED
: Energized when the controlled temperature probe is within specified tolerance of
set point.
NOTE
The controlling probe in perishable range will be the SUPPLY air probe and the controlling probe in
frozen range will be the RETURN air probe.
5.
ALARM - Red LED
: Energized when there is an active or an inactive shutdown alarm in the alarm queue.
6.
SUPPLY - Yellow LED
: Energized when the supply air probe is used for control. When this LED is illumi-
nated, the temperature displayed in the AIR TEMPERATURE display is the reading at the supply air probe.
This LED will flash if dehumidification is enabled.
7.
RETURN - Yellow LED
: Energized when the return air probe is used for control. When this LED is illumi-
nated, the temperature displayed in the AIR TEMPERATURE display is the reading at the return air probe.
This LED will flash if dehumidification is enabled.
Figure 4.3 Display Module
4.1.3
Controller
CAUTION
!
Do not remove wire harnesses from controller modules unless you are grounded to the unit
frame with a static safe wrist strap.
CAUTION
!
Unplug all controller module wire harness connectors before performing arc welding on any
part of the container.
NOTE
Do not attempt to use an ML2i PC card in an ML3 equipped unit. The PC cards are physically different
and will result in damage to the controller.
NOTE
Do not attempt to service the controller modules. Breaking the seal will void the warranty.
COOL
HEAT
DEFROST IN RANGE
ALARM
SUPPLY RETURN
SETPOINT/Code
AIR TEMPERATURE/Data