4–17
T-354
4.6.13
DataCORDER Alarms
Alarm display is an independent DataCORDER function. If an operating parameter is outside of the expected
range or a component does not return the correct signals back to the DataCORDER an alarm is generated. The
DataCORDER contains a buffer of up to eight alarms. A listing of the DataCORDER alarms is provided in
. Refer to
for configuration information.
To display alarm codes:
a. While in the Default Display mode, press the ALT. MODE & ALARM LIST keys. This accesses the Data
CORDER Alarm List Display Mode, which displays any alarms stored in the Alarm Queue.
b. To scroll to the end of the alarm list, press the UP AR ROW. Depressing the DOWN ARROW key will
scroll the list backward.
c. The left display will show "AL#" where # is the alarms number in the queue. The right display will show
"AA##," if the alarm is active, where ## is the alarm number. "IA##," will show if the alarm is inactive.
d. "END" is displayed to indicate the end of the alarm list if any alarms are active. "CLEAr" is displayed if all
the alarms in the list are inactive.
e. If no alarms are active, the Alarm Queue may be cleared. The exception to this rule is the DataCORDER
Alarm Queue Full alarm (AL91), which does not have to be inactive in order to clear the alarm list. To
clear the alarm list:
1. Press the ALT. MODE & ALARM LIST keys.
2. Press the UP/DOWN ARROW key until "CLEAr" is displayed.
3. Press the ENTER key. The alarm list will clear and "
-----
" will be displayed.
4. Press the ALARM LIST key. "AL" will show on the left display and "
-----
" on the right display when
there are no alarms in the list.
5. Upon clearing of the Alarm Queue, the Alarm light will be turned off.
Table 4–4 Controller Configuration Variables
CONFIGURATION
NUMBER
TITLE
DEFAULT
OPTION
CnF01
Bypass Valve Enable
In
Out
CnF02
Evaporator Fan Speed
dS (Dual)
SS (Single)
CnF03
Control Sensors
FOUr
duAL
CnF04
Dehumidification Mode
On
OFF
CnF05
Reserved for future use
-----
n/a
CnF06
Condenser Fan Speed Select
OFF (Single)
On (Variable)
CnF07
Unit Selection, 20FT/ 40FT/45FT
40ft
20ft,45
CnF08
Single Phase/Three Phase Motor
1Ph
3Ph
CnF09
Refrigerant Selection
r134a
r12, r22, bLEnd
CnF10
Two Speed Compressor Logic
Out (Single)
In (Dual)
CnF11
Defrost "Off" Selection
noOFF
OFF
CnF12
TXV/Solenoid Quench Valve
Out (TXV)
In (Solenoid)
CnF13
Unloader
Out
In
CnF14
Condenser Pressure Control (CPC)
In
Out
CnF15
Discharge Temperature Sensor
Out
In