T-354
5–2
1. Make sure that the start-stop switch (ST, on control panel) and circuit breakers CB-1 (in the control box and
CB-2 (on the transformer) are in position “O” (OFF). Plug in and lock the 460VAC power plug at the recepta-
cle on the transformer.
2. Plug the 230VAC (black) cable into a de-energized 190/230VAC, 3-phase power source. Energize the power
source. Set circuit breakers CB-1 and CB2 to position “I” (ON). Close and secure control box door.
Figure 5.1 Autotransformer
5.3
ADJUST FRESH AIR MAKEUP VENT
The purpose of the fresh air makeup vent is to provide
ventilation for commodities that require fresh air circu-
lation. The vent
must be closed
when transporting fro-
zen foods.
Air exchange depends on static pressure differential,
which will vary depending on the container and how the
container is loaded.
Units may be equipped with a vent position sensor
(VPS). The VPS determines the position of the fresh air
vent and sends data to the controller display.
5.3.1
Upper Fresh Air Makeup Vent
Two slots and a stop are designed into the disc for air
flow adjustments. The first slot allows for a 0 to 30% air
flow and the second slot allows for a 30 to 100% air
flow.
To adjust the percentage of air flow, loosen the wing
nut and rotate the disc until the desired percentage of
air flow matches with the arrow. Tighten the wing nut.
To clear the gap between the slots, loosen the wing nut
until the disc clears the stop.
gives air
exchange values for an empty container. Higher values
can be expected for a fully loaded container.
Figure 5.2 Make Up Air Flow Chart
Dual Voltage Modular
Autotransformer
Circuit Breaker (CB-2) 230V
460VAC Power Receptacle
0
30
60
90
120
150
180
210
240
0 10 20 30 40 50 60 70 80 90 100
AIR
FLOW
(CMH)
1-
PERCENT OPEN
69NT40 FRESH AIR MAKEUP
T-BAR
2-
3”
T-BAR
T-BAR
ZERO EXTERNAL STATIC 50HZ
For 60Hz operation multiply curves by 1.2
1/2”
5/8”