AGAGC9PNS01B Gas Conversion Kit, Propane to Natural: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
13
Modulating Gas Valve
L11F061
Fig. 23 – Example of Modulating Furnace Control for ECM Blower
Motor
1. Turn Setup Switch SW1-2 on furnace control ON, see
2. Jumper R-W/W1 and R-W2 thermostat connections on control.
3. When main burners ignite, confirm inlet gas pressure is between
4.5-in. w.c. and 13.6-in. w.c.
4. Remove jumper across R-W/W1 and R-W2 thermostat connections
to terminate call for heat.
5. Turn furnace gas valve switch to OFF position.
6. Turn gas supply manual shutoff valve to OFF position.
7. Turn off furnace power supply.
8. Remove manometer and on some models remove pressure tap
fitting.
9. On some models, apply pipe dope sparingly to the end of inlet gas
pipe plug and install into unused end of 1/8-in. (3 mm) tee. Use a
small back-up wrench on tee when tightening gas inlet pipe plug.
Or, on some models, tighten set screw on inlet tower pressure tap
with a 3/32-in. hex wrench, see
.
CHECK FURNACE AND MAKE ADJUSTMENTS
1. Be sure main gas and electric supplies to furnace are off.
2. On some models, remove 1/8-in. (3 mm) pipe plug from manifold
pressure tap on the outlet end of gas valve and insert pressure tap.
Or, on some models, loosen the set screw on manifold tower
pressure tap no more than one full turn with the 3/32-in. hex
wrench.
3. Attach manometer to manifold pressure tap on gas valve, see
,
,
,
4. Turn gas supply manual shutoff valve to ON position.
5. Turn furnace gas valve switch to ON position.
6. Check all threaded pipe connections for gas leaks.
7. Turn on furnace power supply.
GAS INPUT RATE INFORMATION
See furnace rating plates,see
,
, or
, for input rate. The
input rate for natural gas is determined by manifold pressure and orifice
size.
Modulating gas valve must be set for Maximum Heat first and then set
for Minimum heat on Modulating furnaces.
Two-Stage gas valve must be set for High Heat first and then set for Low
Heat on Two-Stage furnaces.
Furnace gas input rate on rating plate is for installations at altitudes up to
2000 ft. (610 M).
In the U.S.A.; the input rating for altitudes above 2000 ft. (610M) must
be reduced by 2 percent for each 1000 ft. (305 M) above sea level.
In Canada; the input rating must be derated by 5 percent for altitudes of
2000 ft. (610 M) to 4500 ft. (1372 M) above sea level.
The Conversion Kit Rating Plate accounts for high altitude derate.
SET GAS INPUT RATE
A11461
Fig. 24 – Burner Flame
Single Stage Gas Valve
1. Jumper R and W thermostat connections to call for heat, see
2. Check manifold orifices for gas leaks when main burners ignite.
3. Adjust gas manifold pressure, see
.
4. Remove cap that conceals gas valve regulator adjustment screw.
5. Turn adjusting screw counterclockwise (out) to decrease manifold
pressure or clockwise (in) to increase manifold pressure.
6. Replace gas valve regulator seal cap.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death,
and/or property damage.
Never test for gas leaks with an open flame. Use a commercially
available soap solution made specifically for the detection of leaks to
check all connections. A fire or explosion may result causing property
damage, personal injury or loss of life.
24-V THERMOSTAT
TERMINALS
PL2
–
HOT SURFACE
IGNITER & INDUCER
MOTOR CONNECTOR
115-VAC (L2) NEUTRAL
CONNECTIONS
115-VAC (L1) LINE
VOLTAGE CONNECTIONS
EAC-1 TERMINAL
(115-VAC 1.0 AMP MAX.)
PL1
–
LOW VOLTAGE MAIN
HARNESS CONNECTOR
PL3
–
ECM BLOWER
HARNESS
CONNECTOR
TRANSFORMER 24-VAC
CONNECTIONS
3-AMP FUSE
STATUS AND COMM
LED LIGHTS
SW1 SETUP
SWITCHES AND
BLOWER OFF-
DELAY
MODEL PLUG
CONNECTOR
AIR CONDITIONING
(A/C) AIRFLOW
SETUP SWITCHES
COMMUNICATION
CONNECTOR
CONTINUOUS FAN
(CF) AIRFLOW
SETUP SWITCHES
OUTDOOR
AIR TEMP
CONNECTOR
HUMIDIFIER
TERMINAL (24-VAC
0.5 AMP MAX.
FLASH
UPGRADE
CONNECTOR
(FACTORY
ONLY)
SW4 SETUP
SWITCHES
SOFTWARE
VERSION
PART NUMBER AND
DATE CODE WWYY
PL8 - MODULATING
GAS VALVE
CONNECTOR
AVERTISSEMENT
!
RISQUE D’EXPLOSION ET D’INCENDIE
Le non-respect des avertissements de sécurité pourrait d’entraîner des
blessures graves, la mort ou des dommages matériels.
Ne jamais utiliser une flamme nue por vérifier la présence des fuites de
gaz. Pour la vérification de tous les joints, utiliser plutôt une solution
savonneuse commerciale fabriquée spécifiquement pur la détection des
fuites de gaz. Un incendie ou une explosion peut entraîner des
dommages matériels, des blessures ou la mort.
Burner Flame
Burner
Manifold