830CA: Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
26
Table 11 – Air Delivery - CFM (With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See Notes 1 and 2)
Size:
36040C17
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2-3
SW2-2
SW2-1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1275
1310
1305
1315
1310
1305
1305
1295
1290
1270
CF Switches
SW3-3
SW3-2
SW3-1
Low-Clg Default:
OFF
OFF
OFF
1275
1310
1305
1315
1310
1305
1305
1295
1290
1270
Cooling Airflow
(SW2)
Low-Cooling Airflow
(SW3)
OFF
OFF
ON
530
545
545
535
505
495
485
See Note 4
OFF
ON
OFF
715
705
730
730
735
735
740
725
720
695
OFF
ON
ON
870
910
925
925
935
935
925
915
910
900
ON
OFF
OFF
1100
1090
1080
1110
1120
1120
1110
1110
1100
1095
ON
OFF
ON
1275
1310
1305
1315
1310
1305
1305
1295
1290
1270
ON
ON
OFF
1445
1480
1480
1480
1475
1455
1415
1375
1335
1295
ON
ON
ON
1445
1480
1480
1480
1475
1455
1415
1375
1335
1295
Maximum Clg Airflow
1635
1605
1565
1525
1490
1455
1415
1375
1335
1295
CF Switches
SW3-3
SW3-2
SW3-1
Cont. Fan Default:
OFF
OFF
OFF
530
545
545
535
505
495
485
See Note 4
Continuous Fan
Airflow
(SW3)
OFF
OFF
ON
530
545
545
535
505
495
485
See Note 4
OFF
ON
OFF
715
705
730
730
735
735
740
725
720
695
OFF
ON
ON
870
910
925
925
935
935
925
915
910
900
ON
OFF
OFF
1100
1090
1080
1110
1120
1120
1110
1110
1100
1095
ON
OFF
ON
1100
1090
1080
1110
1120
1120
1110
1110
1100
1095
ON
ON
OFF
1100
1090
1080
1110
1120
1120
1110
1110
1100
1095
ON
ON
ON
1100
1090
1080
1110
1120
1120
1110
1110
1100
1095
Heating (SW1)
Heating Airflow
760
765
790
790
800
800
800
790
775
755
Size:
48060C17
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2-3
SW2-2
SW2-1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1460
1475
1500
1500
1480
1440
1395
1355
1310
1255
CF Switches
SW3-3
SW3-2
SW3-1
Low-Clg Default:
OFF
OFF
OFF
540
565
555
555
535
See Note 4
Cooling Airflow
(SW2)
Low-Cooling Airflow
(SW3)
OFF
OFF
ON
540
565
555
555
535
See Note 4
OFF
ON
OFF
715
735
745
760
765
See Note 4
OFF
ON
ON
865
910
935
950
965
955
950
955
955
945
ON
OFF
OFF
1120
1125
1130
1145
1160
1165
1165
1160
1150
1150
ON
OFF
ON
1275
1295
1315
1335
1340
1345
1340
1335
1310
1255
ON
ON
OFF
1460
1475
1500
1500
1480
1440
1395
1355
1310
1255
ON
ON
ON
1460
1475
1500
1500
1480
1440
1395
1355
1310
1255
Maximum Clg Airflow
1620
1595
1565
1525
1480
1440
1395
1355
1310
1255
CF Switches
SW3-3
SW3-2
SW3-1
Cont. Fan Default:
OFF
OFF
OFF
540
565
555
555
535
See Note 4
Continuous Fan
Airflow
(SW3)
OFF
OFF
ON
540
565
555
555
535
See Note 4
OFF
ON
OFF
715
735
745
760
765
See Note 4
OFF
ON
ON
865
910
935
950
965
955
950
955
955
945
ON
OFF
OFF
1120
1125
1130
1145
1160
1165
1165
1160
1150
1150
ON
OFF
ON
1275
1295
1315
1335
1340
1345
1340
1335
1310
1255
ON
ON
OFF
1460
1475
1500
1500
1480
1440
1395
1355
1310
1255
ON
ON
ON
1460
1475
1500
1500
1480
1440
1395
1355
1310
1255
Heating (SW1)
Heating Airflow
3
960
995
1015
1020
1030
1050
1055
1060
1055
1045