TROUBLESHOOTING CHARTS
TROUBLE
COMMON CAUSE
REMEDY
UNIT WILL NOT RUN.
Blown Fuse.
Check power for “live” circuit. If outlet is
“dead” but building has power, replace the
fuse. Try to determine the cause of the over-
load or short circuit
Low Voltage.
Check outlet with voltmeter. Should check
115V plus or minus 10%.
If circuit is overloaded, either reduce load or
have electrician install separate circuit.
If unable to remedy any other way, install
auto-transformer.
Open motor or temperature control.
Jumper across terminals of control. If unit
runs and connections are all tight, replace
control. Power element may have lost
charge or points may be dirty. Repair or
replace thermostat.
Open relay.
Check relay. Replace if necessary.
Open overload.
Check overload. Replace if necessary
Open compressor.
Check compressor. Replace if necessary.
Open service cord.
Check with ohmmeter at unit. If no circuit
and current is indicated at outlet, replace
or repair.
Broken lead to compressors or cold
Repair or replace broken leads.
control.
Service cord not plugged in.
Plug in cord.
CABINET TOO WARM.
Thermostat position set too warm, not
Turn knob to colder position.
allowing unit to operate often enough.
Fan motor not running.
Check and replace fan motor if necessary.
Shortage of refrigerant
Check for leaks. Repair, evacuate and
recharge system.
Not enough air circulation around
Relocate cabinet or provide clearance to
cabinet.
allow sufficient circulation.
Dirty condenser or obstructed
Clean the condenser and the ducts.
condenser ducts.
Thermostat control capillary not
Refer back to removal/installation
properly installed.
instructions detailed in this manual.
TROUBLESHOOTING
93
Summary of Contents for BT30RF- EXPR
Page 15: ...SECTION II...
Page 26: ...ELECTRICAL BOX WIRING DIAGRAM 00 0056 00 WIRING DIAGRAM 25...
Page 27: ...ELECTRICAL BOX WIRING DIAGRAM 00 0057 00 26 WIRING DIAGRAM...
Page 28: ...ELECTRICAL BOX WIRING DIAGRAM 00 0064 00 WIRING DIAGRAM 27...
Page 49: ...INSTRUCTIONS SOLID DOOR REMOVAL INSTALLATION ADJUSTMENT 48 MAINTENANCE REPAIR...
Page 63: ...CASTER INSTALLATION INSTRUCTIONS 62 MAINTENANCE REPAIR...
Page 69: ...ELECTRICAL REFRIGERATION INFORMATION BT30RF EXPR Explosion Proof Refrigerator Freezer...
Page 79: ...ELECTRICAL REFRIGERATION INFORMATION ST260RI ST260RIR...
Page 81: ...MODULE 1 ANALOGIC PARAMETERS MODULE 1 PARAMETERS 83...
Page 83: ...MODULE 1 DAYTRONICS PARAMETERS MODULE 1 PARAMETERS 85...
Page 102: ...EVAPORATOR FAN SHROUD ASSEMBLY 104 EVAPORATOR FAN SHROUD ILLUSTRATION...
Page 105: ...EVAPORATOR FAN AREA BT30RSFMS BT50RSFMS EVAPORATOR FAN AREA ILLUSTRATION 107...