20
1"(2.54cm)
Maximum
Combustion
Air
Vent
6 - COMBUSTION AIR AND VENT PIPING
FIGURE 6-4
Maintain 12"
clearance above
highest anticipated
snow level or grade
* See Note
Below
Vent
Combustion
Air
1" (2.54cm)
Maximum
Roof overhang
36"(0.9m) Minimum
Maintain 12"(30cm)
clearance above highest
anticipated snow level or
grade
12" (30cm) Minimum
FIGURE 6-5
*Must be less than 4" or greater than 24" Horizontal dis-
tance between end bells of each air intake to prevent fl ue
gas recirculation.
FIGURE 6-7
46-3/4" (1.2 m)
Vent
Combustion Air
1"(2.54cm)
Maximum
**See
Note
*2 or 3" (5.0 or 7.6cm) Diameter
PVC intake/combustion air
Elbow fi eld
supplied
Combustion Air
Note: Securing strap must
be fi eld installed to prevent
movement of termination
kit in side wall
*2" (5.0cm) Diameter = 41" Length (1.0m))
3" (7.6cm) Diameter = 47" Length (1.2m)
** Note Overall length may be modifi ed by cutting or
extending both combustion air and vent pipes. 12" is
minimum allowable length and 60" is maximum allowable
length for this dimension. SDR-26 PVC (D2241) only may
be used for extending pipes. Do not use Schedule 40 PVC
or use couplings to extend pipes. Dimension will change if
intake/vent pipes are lengthened or shortened.
1" (2.54cm)
Maximum
OD 3
½
"
(8.9cm)
- *2"
(5.0cm)
kit
OD 4
½"
(11.4cm)
- 3"
(7.6cm)
kit
* Note: 2" For use with models 050/075/100.
3" For use with models 075/100/150/200
Summary of Contents for BWMAAN000050
Page 46: ...46 13 TROUBLE SHOOTING ...
Page 48: ...48 13 TROUBLE SHOOTING ...
Page 53: ...53 14 WIRING DIAGRAM 14 1 Connection Diagram ...
Page 54: ...54 14 WIRING DIAGRAM 14 2 Schematic Diagram of Ladder Form ...
Page 60: ...60 APPENDIX A CONTROL MODULE ...
Page 61: ...61 APPENDIX A CONTROL MODULE ...
Page 64: ...64 APPENDIX A CONTROL MODULE ...
Page 70: ...70 NOTES ...
Page 71: ...71 Date Service Performed Company Name Tech Initials Company Address Phone ...
Page 72: ...CAC BDP 7310 West Morris St Indianapolis IN 48231 ...