18
Controls, Systems and Operations
Models C708/C709/C716/C717
Universal Control Programming
Operating Screen
Descriptions
______________________________
The fluorescent display located in the center of the
control panel is normally blank during the daily
operation of the machine. The display is activated
when the SEL symbol or the Manager’s Menu is
selected. The display screen will also alert the
operator of specific faults detected by the control.
Note: The displays illustrated in this section are
those seen on the Models C708/C709. The Model
C716/C717 versions may vary slightly.
Power Up Memory (Initializing)
The seven segment display should display “00”
during the initializing sequence.
When the machine is powered, the control system
will initialize to perform a system check. The screen
will display “INITIALIZING”. There will be four types
of data the system will check: LANGUAGE,
SYSTEM DATA, CONFIG DATA, and LOCKOUT
DATA.
Language Initialization
The UVC platform supports multiple languages by
keeping specific strings in battery backed RAM.
After power-up or a CPU reset, the strings are
tested to see if the language strings are present and
not corrupted. If the strings are present and not
corrupted, initialization continues. Otherwise, the
operator is prompted to select a language. While
language strings are being checked for integrity, the
following screen is displayed.
Initializing
Language
Note:
If there is a language initialization fault, the
machine will force a language selection prior to the
initializing sequence. The standard menu LED’s
should light, as if it were in a menu. If a language
has been selected, the unit is powered down, the
machine should not ask for a language unless there
is another language initialization fault. English is the
factory default setting.
System Data
System data is protected separately from the rest of
the data in memory. System data includes variables
that change frequently such as the mode the
machine is in, lockout status, serving counters, fault
codes, and others. While System Data is being
checked the following screen is displayed.
Initializing
System Data
If the System Data is corrupted, the machine is set
to OFF, the serving counters are set to zero, and the
faults are cleared. A “SYSTEM CRC ERR” fault is
set and displayed on the VFD. An acknowledgement
(SEL key) is required.
Configuration Data
Configuration data is separate from the rest of the
data in the memory. Configuration data is
information entered through operator and service
menus. While Configuration Data is being checked
the following screen is displayed.
Initializing
Config Data
If Configuration data is corrupted, all user and
service settings are set to defaults. A “CONFIG
CRC ERR” fault is set and displayed on the VFD.
The system will continue to operate in its previous
mode but according to default settings.
Summary of Contents for C708
Page 1: ...Models C708 C709 C716 C717 Heat Treatment Soft Serve Freezers Service Manual 059061 S 6 15 05 ...
Page 2: ......
Page 6: ...Table of Contents Models C708 C709 C716 C717 Notes ...
Page 22: ...16 Introduction Models C708 C709 C716 C717 Notes ...
Page 49: ...43 Models C708 C709 C716 C717 Systems Controls and Operations C708 C709 Control Overview ...
Page 50: ...44 Systems Controls and Operations Models C708 C709 C716 C717 C716 C717 Control Overview ...
Page 53: ...47 Models C708 C709 C716 C717 Systems Controls and Operations Refrigeration Schematic ...
Page 70: ...64 Troubleshooting Models C708 C709 C716 C717 Notes ...
Page 73: ...67 Models C708 C709 C716 C717 Parts Notes ...
Page 74: ...68 Parts Models C708 C709 C716 C717 Model C708 Exploded View ...
Page 78: ...72 Parts Models C708 C709 C716 C717 Model C709 Exploded View ...
Page 82: ...76 Parts Models C708 C709 C716 C717 Model C716 Exploded View ...
Page 86: ...80 Parts Models C708 C709 C716 C717 Model C717 Exploded View ...
Page 133: ...C708 C709 057010 27 Rev 6 05 ...
Page 134: ...C708 C709 057010 33 Rev 6 05 ...
Page 135: ...C708 C709 057010 40 Rev 6 05 ...
Page 136: ...C708 C709 057010 58 Rev 6 05 ...
Page 137: ...Model C716 059900 27 Rev 2 06 ...
Page 138: ...Model C716 059900 27 Inset 1 2 06 ...
Page 139: ...Model C716 059900 27 Inset 2 2 06 ...
Page 140: ...Model C716 059900 33 Rev 2 06 ...
Page 141: ...Model C716 059900 40 Rev 2 06 ...
Page 142: ...Model C716 059900 58 Rev 2 06 ...
Page 143: ...Model C717 059901 27 6 05 ...
Page 144: ...Model C717 059901 27 Inset 1 6 05 ...
Page 145: ...Model C717 059901 27 Inset 2 6 05 ...
Page 146: ...Model C717 059901 33 6 05 ...
Page 147: ...Model C717 059901 40 6 05 ...
Page 148: ...Model C717 059901 58 6 05 ...