Before you call for service...

...check for several easily--solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow. Check the air filter for dirt. Check

for blocked return--air or supply--air grilles. Be sure they are open
and unobstructed. If these checks do not reveal the cause, call your

servicing dealer.

If your unit is not operating at all, check the following list for

easy solutions:

(

) Check to be sure that your thermostat temperature selector is

set below the indoor temperature during the cooling season or

above the indoor temperature during heating season. Be sure the

SYSTEM switch or MODE control is in the COOL or HEAT and
not OFF.
( ) If your unit still fails to operate, call your servicing dealer for
troubleshooting and repairs. Specify the model and serial numbers

of your unit. (Record them in this manual in the space provided.) If

the dealer knows exactly which unit you have, he may be able to
offer suggestions over the phone, or save valuable time through

knowledgeable preparation for the service call.

In Case of Trouble

If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.

MANIFOLD

BURNER

BURNER FLAME

C99021

Fig. 10 -- Monoport Burner

Copyright 2017 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Edition Date: 05/17

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: OM48VT---03

Replaces: OM48EZ--- VT--- 07

Summary of Contents for Comfort 48VT-C

Page 1: ...__________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address______________________________________ _____________________________________________ Phone Number _____________________...

Page 2: ...ury death or property damage Installation and servicing of this equipment can be hazardous due to mechanical and electrical components Only trained and qualified personnel should install repair or service this equipment WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death or property damage Do not use this unit if any part has been und...

Page 3: ...re to start unit The induced draft combustion air fan will start Main gas valve will open and main burners should ignite within 5 seconds If the burner does not light within 5 seconds the ignition module will go into a Retry Mode after a period of approximately 22 seconds following the 5 second ignition period If the burners do not light within 15 minutes of the initial call for heat there is a lo...

Page 4: ...FAN control and a SYSTEM or MODE control Refer to your thermostat owner s manual for more information To better protect your investment and to eliminate unnecessary service calls familiarize yourself with the following facts 1 During heat pump heating increasing the thermostat setting more than 2_F 1 1_C may cause the supplemental gas heat to be turned on for a short period of time to satisfy the ...

Page 5: ...5 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 4 To Start Unit Gas Heat ...

Page 6: ...5 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 5 To Shut Off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 Fig 6 To Start Unit Electric Cooling ...

Page 7: ...m the top of the unit is 48 in 1219 mm Clearance of at least 36 in 914 mm is required on sides except the power entry side 42 in 1067 mm clearance and the duct side 12 in 305 mm minimum clearance Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to maintain yourself please carefully consider the following FIRE EXPLOSION ELECTRICAL SHOCK AND CUT HAZARD ...

Page 8: ...r s by pulling it out and through the unit filter access door If filter is dirty replace both filters with new ones Units with bent indoor coils install 24 x 18 x 1 610 x 457 x 25 mm filter first and then install 24 x 16 x 1 610 x 406 x 25 filter When installing the new filters note the direction of the airflow arrows on the filter frame which should be pointing at the indoor coil 3 Reinstall filt...

Page 9: ... an especially loud noise when the main burners are ignited shut down the heating section and call your dealer WARNING BURN HAZARD Failure to follow this caution may result in personal injury Components in heating section may be hot after unit has been started up When observing flame be careful not to get close to or touch heating components CAUTION Regular Dealer Maintenance In addition to the ty...

Page 10: ...he COOL or HEAT and not OFF If your unit still fails to operate call your servicing dealer for troubleshooting and repairs Specify the model and serial numbers of your unit Record them in this manual in the space provided If the dealer knows exactly which unit you have he may be able to offer suggestions over the phone or save valuable time through knowledgeable preparation for the service call In...

Reviews: