CUT HAZARD

Failure to follow this caution may result in personal injury.
When removing access panels or performing maintenance

functions inside your unit, be aware of sharp sheet metal

parts and screws. Although special care is taken to reduce

sharp edges to a minimum, be extremely careful when

handling parts or reaching into the unit.

!

CAUTION

UNIT INTRODUCTION

This unit is a small packaged gas heat/electric heat pump system
that can utilize both the efficiency of heat pump heating and the

comfort of gas heating. The system will optimize for ideal heating,

depending on several factors. This unit

uses

Puron

, the

environmentally balanced refrigerant, for cooling and heat pump

heating.

Starting or Shutting Off Unit

NOTE

: Your combination heating/cooling unit is equipped with

an automatic direct spark ignition and power combustion blower.

To start unit gas heat:

Refer to Fig. 2 for location of unit front access panel. Refer to Fig.

4 for location of gas valve. Refer to Fig. 4 while proceeding with
the following steps.

1. Set the temperature selector on room thermostat to the low-

est temperature setting and set system switch to Emergency

Heat.

2. Close the external manual gas shutoff valve.
3. Turn off the electrical supply to the unit.
4. Remove the control access panel with a 5/16--in. nut driver.

(See Fig. 2.)

COMPRESSOR 
ACCESS PANEL

BLOWER
ACCESS
PANEL

CONTROL
ACCESS
PANEL

A170032

Fig. 2 -- Unit Access Panels

5. Move the selector switch on the internal gas valve to the

OFF position and wait 5 minutes.

6. Move the selector switch on the internal gas valve to the ON

position.

7. Replace the control access panel.
8. Turn on the electrical supply to unit.
9. Open the external manual gas shutoff valve.

10. Set the temperature selector on room thermostat slightly

above room temperature to start unit. The induced--draft
combustion air fan will start. Main gas valve will open and
main burners should ignite within 5 seconds. If the burner

does not light within 5 seconds, the ignition module will go
into a Retry Mode after a period of approximately 22

seconds (following the 5--second ignition period). If the
burners do not light within 15 minutes of the initial call for
heat, there is a lockout.

11. Set the temperature selector on room thermostat to desired

setting.

FIRE AND EXPLOSION HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
1. If the main burners fail to light, or the blower fails to

start, shut down gas heating section and call your dealer for

service.

2. Never attempt to manually light the main burners on unit

with a match, lighter, or any other flame. If the electric

sparking device fails to light the main burners, refer to the

following shutdown procedures, then call your dealer as

soon as possible.

!

WARNING

Burners

Gas Valve

Flue Hood

A170033

Fig. 3 -- Gas Heating/Electric Cooling Unit with Access Panel

Removed

T

o shut off unit gas heat:

FIRE,

EXPLOSION,

ELECTRICAL

SHOCK

HAZARD

Failure to follow this warning could result in personal

injury, death, and/or property damage.
Do not turn off the electrical power to unit without first

turning off the gas supply.

!

WARNING

NOTE

: If the unit is being shut down because of a malfunction,

call your dealer as soon as possible.

Should overheating occur or the gas supply fail to shut off, shut

off the external manual gas valve to the unit before shutting off

the electrical supply. Do not use this unit if any part has been under
water. Immediately call a qualified service technician to inspect the

unit and to replace any part of the control system and any gas
control which has been under water.
Refer to Fig. 5 while proceeding with the following steps.

1. Set the temperature selector on room thermostat to lowest

temperature setting and set system SWITCH to OFF.

Summary of Contents for Comfort 48VT-C

Page 1: ...__________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed________________________________ DEALERSHIP CONTACT INFORMATION Company Name_______________________________ Address______________________________________ _____________________________________________ Phone Number _____________________...

Page 2: ...ury death or property damage Installation and servicing of this equipment can be hazardous due to mechanical and electrical components Only trained and qualified personnel should install repair or service this equipment WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death or property damage Do not use this unit if any part has been und...

Page 3: ...re to start unit The induced draft combustion air fan will start Main gas valve will open and main burners should ignite within 5 seconds If the burner does not light within 5 seconds the ignition module will go into a Retry Mode after a period of approximately 22 seconds following the 5 second ignition period If the burners do not light within 15 minutes of the initial call for heat there is a lo...

Page 4: ...FAN control and a SYSTEM or MODE control Refer to your thermostat owner s manual for more information To better protect your investment and to eliminate unnecessary service calls familiarize yourself with the following facts 1 During heat pump heating increasing the thermostat setting more than 2_F 1 1_C may cause the supplemental gas heat to be turned on for a short period of time to satisfy the ...

Page 5: ...5 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 4 To Start Unit Gas Heat ...

Page 6: ...5 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 5 To Shut Off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 Fig 6 To Start Unit Electric Cooling ...

Page 7: ...m the top of the unit is 48 in 1219 mm Clearance of at least 36 in 914 mm is required on sides except the power entry side 42 in 1067 mm clearance and the duct side 12 in 305 mm minimum clearance Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to maintain yourself please carefully consider the following FIRE EXPLOSION ELECTRICAL SHOCK AND CUT HAZARD ...

Page 8: ...r s by pulling it out and through the unit filter access door If filter is dirty replace both filters with new ones Units with bent indoor coils install 24 x 18 x 1 610 x 457 x 25 mm filter first and then install 24 x 16 x 1 610 x 406 x 25 filter When installing the new filters note the direction of the airflow arrows on the filter frame which should be pointing at the indoor coil 3 Reinstall filt...

Page 9: ... an especially loud noise when the main burners are ignited shut down the heating section and call your dealer WARNING BURN HAZARD Failure to follow this caution may result in personal injury Components in heating section may be hot after unit has been started up When observing flame be careful not to get close to or touch heating components CAUTION Regular Dealer Maintenance In addition to the ty...

Page 10: ...he COOL or HEAT and not OFF If your unit still fails to operate call your servicing dealer for troubleshooting and repairs Specify the model and serial numbers of your unit Record them in this manual in the space provided If the dealer knows exactly which unit you have he may be able to offer suggestions over the phone or save valuable time through knowledgeable preparation for the service call In...

Reviews: