Infinity™ 96

Model 58MVP

Deluxe 4-Way Multipoise

Direct-Vent Variable-Speed

Deluxe Condensing Gas Furnace

 

Series 170

Input Capacities: 40,000 thru 120,000 Btuh

 

Copyright 2004 Carrier Corporation

Form 58MVP-11PD

 

Comfort Heat™ technology, 
the ultimate in
heating comfort . . .

 

The Carrier Infinity 96 with 
ComfortHeat technology achieves 
the optimum combination of comfort 
and efficency.
The Infinity 96 achieves industry-
leading ultra-high efficiency at up to 
96.6 percent Annual Fuel 
Utilization Efficiency (AFUE). 
Efficient performance is enhanced 
through the variable-speed 
design. To maintain ideal comfort, 
ComfortHeat technology automati-
cally adjusts the heating level, maxi-
mizing the use of low heating levels 
that produce near silent furnace opera-
tion while meeting the exact heating 
needs. This unit is designed to keep the 
indoor temperature within 1 degree of 
the thermostat setpoint. Because it op-
erates in low heat most of the time, the 
Infinity 96 uses up to 80% less power 
than single-capacity furnaces.
In addition to providing ultimate com-
fort, the Infinity 96 has a sealed com-
bustion system. This system brings 
combustion air from outdoors to the 
furnace and vents flue gases safely 
outside the home. Because it is sealed, 
operational noise is minimal. A sealed 
combustion system also means fewer 
cold drafts and less air infiltration.
Quality materials are the key behind the 
Infinity 96’s outstanding performance. 
Carrier stands behind quality. We offer 
lifetime warranty protection* on the 
heat exchangers, the heart of the 
Infinity 96. The rest of the unit is 
backed by a  limited 5-year warranty.
The Infinity 96 is available in 6 
heat/airflow combinations. The unit 
has a 4-way multipoise design and can 

 

Summary of Contents for Deluxe 58MVP

Page 1: ...ion while meeting the exact heating needs This unit is designed to keep the indoor temperature within 1 degree of the thermostat setpoint Because it op erates in low heat most of the time the Infinity 96 uses up to 80 less power than single capacity furnaces In addition to providing ultimate com fort the Infinity 96 has a sealed com bustion system This system brings combustion air from outdoors to...

Page 2: ... engineered and manufactured under an ISO 9001 registered quality system Venting The combustion air and vent pipes can terminate through a side wall or through the roof when used with a factory authorized vent termination kit Blower Access Panel Switch Automatically shuts off 115 v power to furnace whenever blower access panel is opened Reliable Heat Exchanger Design The primary heat exchanger is ...

Page 3: ...es ensure adequate flow of flue products through furnace and out vent system Inducer motor Pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety Condensate drain connection Collects moisture condensed during combustion process Heavy duty blower Circulates air across the heat exchangers to transfer heat into the home Air filter and retainer May be used for ...

Page 4: ...EDIA FILTER WITH END CAPS 24 IN 6 pack EXPXXLMC0024 X X REPLACEMENT EZ FLEX FILTER 16 IN 10 pack EXPXXFIL0016 X REPLACEMENT EZ FLEX FILTER 20 IN 10 pack EXPXXFIL0020 X X X REPLACEMENT EZ FLEX FILTER 24 IN 10 pack EXPXXFIL0024 X X UNFRAMED FILTER ONE INCH 16 X 25 KGAWF1306UFR 6 pack S X S S S UNFRAMED FILTER ONE INCH 20 X 25 KGAWF1406UFR 6 pack X X X UNFRAMED FILTER ONE INCH 24 X 25 KGAWF1506UFR 6 ...

Page 5: ... configured for multiple use staging it must be configured for each specific application NON PROGRAMMABLE THERMOSTAT SELECTION TSTATCCNAC01 B For use with 1 spd Air Conditioner deg F c Auto Changeover TSTATCCNHP01 B For use with 1 spd Air Conditioner deg F C Auto Changeover TSTATCCN2S01 B For use with 2 spd Air Conditioner deg F C Auto Changeover TSTATCCPRH01 B For multi use stage configurations d...

Page 6: ...P fur naces when installed in downflow applications CONTROL CENTER INDUCER ASSEMBLY FLASH UPGRADE CONNECTOR FACTORY ONLY ACRDJ AIR CONDITIONING RELAY DISABLE JUMPER HUMIDIFIER TERMINAL 24 VAC 0 5 AMP MAX CONTINUOUS FAN CF AIRFLOW SETUP SWITCHES COMMUNICATION CONNECTOR AIR CONDITIONING A C AIRFLOW SETUP SWITCHES MODEL PLUG CONNECTOR SW1 SETUP SWITCHES AND BLOWER OFF DELAY STATUS AND COMM LED LIGHTS...

Page 7: ...idual zones of the home This is accomplished through a series of electronic dampers and remote room sensors The 4 zone system is shown A94336 ENERGY HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level Especially useful for today s tighter constructed houses Energy rec...

Page 8: ...3 7 93 7 93 7 93 7 93 7 INPUT BTUH Low 26 000 39 000 52 000 52 000 65 000 78 000 High 40 000 60 000 80 000 80 000 100 000 120 000 SHIPPING WEIGHT Lb 205 170 182 204 203 234 CERTIFIED TEMP RISE RANGE F Low 25 55 50 80 50 80 50 80 50 80 50 80 High 30 60 35 65 35 65 35 65 45 75 45 75 CERTIFIED EXT STATIC PRESSURE ESP Heating 0 10 0 12 0 15 0 15 0 20 0 20 In wc Cooling 0 50 0 50 0 50 0 50 0 50 0 50 AI...

Page 9: ... Cooling 1400 0 1 0 1370 1385 1385 1395 1395 1395 1395 1400 1395 1390 5 Ton A C Cooling 1750 0 1 0 1750 1750 1750 1750 1750 1750 1745 1740 1735 1725 Maximum 2000 0 1 0 2000 2000 2000 2000 1990 1975 1950 1925 1900 1865 100 20 Low Heat 920 0 1 0 920 915 915 920 920 920 915 900 895 890 High Heat 1525 0 1 0 1525 1525 1525 1525 1520 1515 1515 1515 1515 1515 2 Ton A C Cooling 700 0 0 50 700 700 700 690 ...

Page 10: ...0 0 1 0 298 340 384 417 458 493 534 574 607 647 5 Ton A C Cooling 1750 0 1 0 587 631 664 724 772 815 861 907 943 988 Maximum 2000 0 1 0 839 911 973 1029 1066 1104 1134 1149 1170 1182 100 20 Low Heat 920 0 1 0 113 136 159 186 221 243 263 285 316 340 High Heat 1525 0 1 0 378 419 448 486 518 561 606 650 696 730 2 Ton A C Cooling 700 0 0 50 74 89 109 126 146 2 1 2 Ton A C Cooling 875 0 0 50 99 124 147...

Page 11: ...OX DRAIN CONNECTION 1 2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4 26 4 FURNACE SIDE FURNACE SIDE 1 2 1 1 4 26 4 3 4 5 3 4 5 4 SIDE VIEW FRONT VIEW END VIEW FRONT VIEW 3 4 DOWNFLOW AND ALTERNATE E...

Page 12: ...TES 1 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements above...

Page 13: ...hout CD5 or CK5 Coil Assembly or KCAKC Coil Box 18 5 8 19 20 1 4 20 3 8 2 24 1 2 Furnace with or without CD5 or CK5 Coil Assembly or KCAKC Coil Box 22 1 8 19 23 3 4 20 3 8 1 A97427 Assembled A88207 Disassembled LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION A00309 A Media Filter Cabinet A B 16 17 16 20 21 20 24 25 24 23 5 8 23...

Page 14: ... wire 208 230 OR 460 VOLT THREE PHASE 208 230 VOLT SINGLE PHASE WHT BLK WHT BLK W W1 W2 Y Y2 G NOTES 1 2 3 Electrical data Permissible limits of the voltage range at which the unit will operate satisfactorily Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop Time delay type is recommended Typical wiring schematic UNIT SIZE 040 14 06...

Page 15: ...A NA 3 63 62 62 61 61 61 3001 to 4000 040 14 2 Pipe or 2 In Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 060 14 2 Pipe or 2 In Concentric 1 1 2 42 37 32 27 22 17 2 70 70 70 70 70 70 080 14 080 20 2 Pipe or 2 In Concentric 1 1 2 25 20 15 10 5 NA 2 70 70 70 70 70 70 100 20 2 Pipe or 2 In Concentric 2 38 33 28 23 18 13 2 1 2 70 70 70 70 70 70 120 20 2 Pipe or 3 In Concentric 3 29 24 10 NA N...

Page 16: ...8 67 66 64 080 14 080 20 2 Pipe or 2 In Concentric 1 1 2 20 15 10 5 NA NA 2 70 70 68 67 62 57 100 20 2 Pipe or 2 In Concentric 2 31 26 21 16 11 6 2 1 2 70 70 68 67 66 64 120 20 2 Pipe or 3 In Concentric 3 49 48 47 45 44 43 7001 to 8000 040 14 2 Pipe or 2 In Concentric 1 1 2 32 27 22 17 12 7 2 66 65 63 62 60 59 060 14 2 Pipe or 2 In Concentric 1 1 2 32 27 22 17 12 7 2 66 65 63 62 60 59 080 14 080 2...

Page 17: ...owable Pipe Length table Insulation thickness based on R value of 3 5 per in UNIT SIZE WINTER DESIGN TEMP F MAX PIPE DIA IN INSULATION THICKNESS IN 0 3 8 1 2 3 4 1 040 14 20 2 21 37 42 50 57 0 2 10 22 25 30 35 20 2 5 14 17 21 25 060 14 20 2 30 55 61 70 70 0 2 16 33 38 46 53 20 2 9 23 26 33 38 080 14 080 20 20 2 37 65 70 70 70 0 2 20 39 45 55 63 20 2 11 27 31 39 45 100 20 20 2 1 2 41 70 70 70 70 0 ...

Page 18: ...earance To Combustible Construction as described below This furnace requires a special venting system Refer to the installation instructions for parts list and method of installation This furnace is for use with schedule 40 PVC PVC DWV CPVC or ABS DWV pipe and must not be vented in common with other gas fired appliances Construction through which vent air intake pipes may be installed is maximum24...

Page 19: ...2307 Closet Downflow Application A02308 COMBUSTION AIR PIPE A C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR OUTDOOR UNIT AIRFLOW FRONT OF FURNACE ...

Page 20: ...038 Printed in U S A PC 101 Form 58MVP 11PD Tab 6a 8a Replaces 58MVP 10PD COMBUSTION AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE Attic Horizontal Application A02309 Crawlspace Horizontal Application A02310 COMBUSTION AIR PIPE VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING ...

Reviews: