440 01 4801 00
57
Specifications subject to change without notice.
NOTE
: If a bypass humidifier is used, setup switch SW1-4
(Comfort/Efficiency) should be in OFF=Efficiency position. This
compensates for the increased temperature in return air resulting
from bypass.
Air Conditioning (A/C) Setup Switches (SW2--6, 7, 8)
The air conditioning setup switches are used to match furnace
airflow to required cooling airflow or high stage cooling airflow
when a two--stage outdoor unit is used. Refer to the Adjustments
section for setup switch configurations.
To set the desired cooling airflow:
1. Remove blower door.
2. Locate A/C setup switches on furnace control.
3. Determine air conditioning tonnage used.
4. Configure the switches for the required cooling airflow.
NOTE
: Incorrect airflow caused by improper A/C switch setup
may cause condensate blow-off or a frozen indoor coil in the
cooling mode.
5. Replace blower door.
Continuous Fan (CF) Setup Switches (SW2--3, 4, 5)
The CF setup switches are used to select desired airflow when
thermostat is in continuous fan mode or to select low-cooling
airflow for two--speed cooling units. Refer to the Adjustments
section for setup switch configurations. To set desired cooling
airflow:
1. Remove blower door.
2. Locate CF setup switches on furnace control.
3. Determine air conditioning tonnage used for low-cooling
(when used) or desired continuous fan airflow.
4. Configure the switches for the required airflow.
5. Replace blower door.
Setup Switches (SW2--1, 2)
The furnace control has two additional setup switches labeled
SW2--1,2.
Setup switch SW2--1 is used for twinning on approved models.
SW2--2 is used to adjust airflow. Refer to the Adjustments section
for setup switch configurations.
Refer to Fig. 60 for configuration of SW2 airflow options.
1. Remove blower door.
2. Locate setup switch SW2 on furnace control.
3. Configure the switches as necessary for the application.
4. Replace blower door.
A190048
Fig. 60 -- Furnace Setup Switch Description