2

 

WELCOME TO A NEW GENERATION OF 
COMFORT

 

Congratulations! In light of rising energy costs, the Weather-
Maker

 

 

  9200, 58MCA, and WeatherMaker Infinity, Mul-

tipoise, Gas-Fired Condensing Furnaces are among the 
soundest investments today’s homeowner can make.

Your new furnace is truly a triumph of technology in home 
heating. A revolutionary design employs 2 heat exchangers 
to “squeeze” out the maximum amount of heat from the fuel 
consumed. In fact, your new furnace is so efficient, over 90%* 
of the heat generated during combustion is captured and 
delivered inside your home. That is more than a 33%* 
increase in heating efficiency over conventional furnaces.

These are among the most energy-efficient furnaces you can 
buy today. They also are among the safest and most depend-
able. We are proud of the technological advances incorpo-
rated into the design of these furnaces. With only minimal 
care, your new furnace will deliver many years of money-
saving home comfort and enjoyment. Spend just a few min-
utes with this manual to learn the operation of your new fur-
nace and the small amount of maintenance it takes to help 
keep it operating at peak efficiency year after year.

 

* The output capacity and any representations of efficiency for this furnace are based on standard Depart-

ment of Energy test procedures.

 

INSTALLATION DATA

 

Date Installed

Dealer Name

Address

City

State

Zip

Telephone

 

FURNACE

 

Product No.

Model No.

Serial No.

 

SPLIT-SYSTEM

 

Product No.

Model No.

Serial No.

 

INDOOR COIL:

 

Product No.

Model No.

Serial No.

1

MODELS 58MXA (SHOWN) AND
58MCA FIXED-CAPACITY FURNACES

2

MODEL 58MVP
VARIABLE-CAPACITY FURNACE

®

• • • • •

• • • • •

• • • • •

U L T R A   H

I G H   E F F

I C I E N C Y

G A S   F U

R N A N C E

®

®

• • • • •

• • • • •

• • • • •

U L T R A   H

I G H   E F F I

C I E N C Y

G A S   F U

R N A N C

E

Summary of Contents for GAS FURNACE 58MVP

Page 1: ...t use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Instal...

Page 2: ...pend able We are proud of the technological advances incorpo rated into the design of these furnaces With only minimal care your new furnace will deliver many years of money saving home comfort and en...

Page 3: ...nger inside Wrings out more heat through condensation Constructed with Polypropylene laminated steel to ensure durability Primary serpentine heat exchanger inside Stretches fuel dollars with the S sha...

Page 4: ...Y CONSIDERATIONS Installation and service of heating equipment can be hazard ous due to gas and electrical components Only trained and qualified personnel should install repair or service heating equi...

Page 5: ...ally signal the furnace to start 11 When the furnace receives the start signal the hot sur face ignitor at the main burners is automatically heated for 15 to 20 sec When the microprocessor control ver...

Page 6: ...ied structure during winter See winterizing proce dures in maintenance section SYSTEM COOL OFF HEAT FAN AUTO ON 50 70 90 50 70 90 18 FILTERING OUT TROUBLE A dirty filter will cause a loss of airflow i...

Page 7: ...n Make sure that all PVC pipes leading into the combustion area and vent are free from any cracks and sags Also check the combustion air intake and vent pipes on the outside of your home for blockage...

Page 8: ...rain connection cap See Fig 30 5 Connect field supplied 1 2 in ID tube to upper inducer housing drain connection 6 Insert field supplied funnel into tube 7 Pour 1 quart of antifreeze into funnel tube...

Page 9: ...ctions around the vent termination If the furnace still fails to operate call your service representative For your convenience record the furnace product and serial numbers on page 2 Should you ever r...

Page 10: ...rmostat switch to call for heat 13 or 33 Limit Switch Lockout 14 or 34 Ignition Lockout or Ignition Proving Fault M Check to be sure manual shut off valve in gas supply pipe is in open position Follow...