GUIDE SPECIFICATIONS

General

System Description

Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory--

authorized conversion kit required for propane); furnish cold air

return plenum; furnish external media cabinet for use with
accessory media filter or standard filter.

Quality Assurance

Unit will be designed, tested and constructed to the current ANSI Z

21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z

21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue Star

R

and Blue Flame

R

labels. Unit

efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the

latest GAMA Consumer’s Directory of Certified Efficiency
Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and

handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available upon request.

Equipment

Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and

dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,

and have infinitely variable speed from 250--1300 RPM operating
only when 24--VAC motor inputs are provided. Blower motor shall

be direct drive and soft mounted to the blower scroll to reduce
vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(X) ________ in. An accessory highly efficient Media Filter is

available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted

galvanized steel.

Infinity ICS

Multi--Stage/Variable Speed Gas Furnace

ECM Inducer Motor
ECM Inducer motor shall be variable speed design, soft mounted

to assembly to reduce vibration transmission.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass 20 gauge corrosion--

resistant aluminized steel of fold--and--crimp sectional design and
applied operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a flow--through design
having a patented interior laminate coating of polypropylene for

greater corrosion resistance with fold--and--crimp design and
applied operating under negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting

codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and

a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including separate blower speeds for

low heat, medium heat, high heat, low cooling, high cooling and

continuous fan. Continuous fan speed may be adjusted from the
thermostat. Cooling airflow will be selectable between 350 or 400

CFM per ton of air conditioning. Features will also include
temporary reduced airflow in the cooling mode for improved

dehumidification when an Infinity Control or Thermidistat is

selected as the thermostat.

Operating Characteristics

Heating capacity shall be _________________ Btuh input;

______________ Btuh output capacity.
Fuel Gas Efficiency shall be 92.1 to 95% AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.

wc. external static pressure.
Dimensions shall be: depth_________in.; width __________in.;

height___________in. (casing only). Height shall be
_________in. with A/C coil and _________________in. overall

with plenum.

Electrical Requirements

Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size

of HACR--type designated circuit breaker shall be _________
amps.

Special Features

Refer to section of the product data identifying accessories and

descriptions for specific features and available enhancements.

Copyright 2007 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 08/07

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: 58MVC---1PD

Replaces: NEW

58MV

C

Summary of Contents for INFINITY ICS 58MVC

Page 1: ...ltration Quality materials are the key behind the Infinityt ICS s outstanding performance Carrier stands behind quality We offer lifetime warranty protection on the heat exchangers the heart of the Infinityt ICS The rest of the furnace is backed by a limited 5 year warranty The Infinityt ICS is available in 5 heat airflow combinations The unit has a 4 way multipoise design and can be installed in ...

Page 2: ...enter The microprocessor control center features state of the art combustion temperature and airflow control to maximize comfort while operating at peak efficiency Combustion control is obtained by taking the inducer motor RPM reading when the medium heat pressure switch makes Using this information the microprocessor maintains a consistent air to fuel ratio independent of vent sizing and conditio...

Page 3: ...s for disposal into home drain system Location in furnace varies 10 Heavy duty blower Circulates air across the heat exchangers to transfer heat into the home 11 Serpentufft secondary condensing heat exchanger inside Wrings out more heat through condensation Constructed with polypropylene laminated steel to ensure durability 12 Primary serpentine heat exchanger inside Stretches fuel dollars with t...

Page 4: ...ensate Neutralizer Kit obtained thru RCD P908 0001 X X X X X Electronic Air Cleaner Model EACB X X X X X Mechanical Air Cleaner Model FILCAB or EZXCAB X X X X X Humidifier Model HUM X X X X X Heat Recovery Ventilator Model HRV X X X X X Energy Recovery Ventilator Model ERV X X X X X UV Lights Model UVL X X X X X EZ Flex Media Filter with end caps 16 in 9 pack EXPXXLMC0016 X EZ Flex Media Filter wi...

Page 5: ...22 X X X Gas Orifice Kit Size 42 Qty 50 KGAHA0150N42 See Installation Instructions for model altitude and heat value usages Gas Orifice Kit Size 43 Qty 50 KGAHA0250N43 Gas Orifice Kit Size 44 Qty 50 KGAHA0350N44 Gas Orifice Kit Size 45 Qty 50 KGAHA0450N45 Gas Orifice Kit Size 46 Qty 50 KGAHA0550N46 Gas Orifice Kit Size 47 Qty 50 KGAHA1550N47 Gas Orifice Kit Size 48 Qty 50 KGAHA850N48 Gas Orifice K...

Page 6: ...r Conditioner _F _C Auto Changeover 5 2 Programmable TSTATCCPDF01 B For use with multi stage applications _F _C Auto Changeover 7 Day Programmable TSTATCCPRH01 B For multi use stage configurations _F _C Auto Changeover 7 Day Programmable SYSTXCCUID01 B Infinityt user interface Model HP 2 Stage thermostat must be field converted to air conditioner operation Hybrid Heat thermostat is used with furna...

Page 7: ...BER MEDIUM HEAT ADJUSTMENT UNDER CAP INLET PRESSURE TAP ON OFF SWITCH HIGH HEAT ADJUSTMENT UNDER CAP BURNER ENCLOSURE REFFERENCE TAP LOW HEAT ADJUSTMENT UNDER CAP MANIFOLD PRESSURE TAP A07422 A92505 A07280 CONTROL CENTER HEAT EXCHANGERS GAS VALVE ______________________________________________________________________________________________________________ Concentric Vent Kit A93086 A concentric ve...

Page 8: ...d through a series of electronic dampers and remote rooom sensors The 4 zone system is shown ENERGY HEAT RECOVERY VENTILATOR Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level Especially useful for today s tighter constructed houses Energy recovery ventilator is shown _______________________...

Page 9: ...5 625 695 800 685 790 875 1005 1095 1260 Heating High 1070 1220 1470 1510 1900 Cooling Max 1400 1375 1975 1950 2060 OUTPUT CAPACITY BTUH ICS Low Upflow 22000 30000 30000 38000 46000 Downflow 23000 30000 30000 38000 46000 Horizontal 21000 30000 30000 38000 45000 Medium Upflow 37000 49000 49000 61000 73000 Downflow 36000 49000 49000 61000 73000 Horizontal 36000 49000 49000 61000 73000 High Upflow 56...

Page 10: ... 660 660 655 655 655 Medium Heat 890 0 0 50 875 890 890 890 890 High Heat 1510 0 1 0 1510 1510 1510 1510 1510 1500 1490 1480 1470 1455 2 Ton A C Cooling 700 0 0 50 700 690 690 690 690 2 1 2 Ton A C Cooling 875 0 0 50 835 845 855 860 865 3 Ton A C Cooling 1050 0 1 0 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 3 1 2 Ton A C Cooling 1225 0 1 0 1170 1190 1205 1220 1225 1225 1225 1225 1225 1225 4...

Page 11: ...nt 2 Pipe Only All Model Sizes 1Ú2 OD INDUCER HOUSING DRAIN CONNECTION 1Ú4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5Ú8 OD COLLECTOR BOX DRAIN CONNECTION 1Ú2 IN PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN FLOW APPLICATIONS OPTIONAL 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION OPTIONAL WIRE TIE GUIDES WHEN USED 1 2 1 3 4 1 3 4 FRONT VIEW SIDE VIEW FURNACE DOOR FURNACE DOOR CONDENSATE TRAP 78 1 4...

Page 12: ...OTES 1 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufacturer s recommendations for equivalent diameters 2 Minimum return air opening at furnace a For 800 CFM 16 in round or 14 1 2 x 12 in rectangle b For 1200 CFM 20 in round or 14 1 2 x 19 1 2 in rectangle c For 1600 CFM 22 in round or 14 1 2 x 23 1 4 in rectangle d For airflow requirements abov...

Page 13: ...82 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in smaller in width and depth than the plenum dimensions shown above A97427 Assembled A88207 Disassembled LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 4 TYP PLENUM OPENING FACTORY SUPPLIED FIELD INSTALLED INSULATION Downflow Subbase A 23 5 8 23 3 8 Furnace Side 23 3 4 Centerline Screw Slots 25 5 8 Duct Side 24 3 8 Openi...

Page 14: ...r maximum 2 voltage drop Time delay type is recommended 115 VOLT FIELD SUPPLIED FUSED DISCONNECT JUNCTION BOX CONTROL BOX 24 VOLT TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 2 NOTE 1 1 STAGE THERMOSTAT TERMINALS FIELD SUPPLIED FUSED DISCONNECT CONDENSING UNIT FURNACE COM R W C Y R G GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIR...

Page 15: ...centric 1 1 2 42 12 8 37 11 2 32 9 8 27 8 2 22 6 7 17 5 2 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 80 000 2 Pipe or 2 In Concentric 1 1 2 25 7 6 20 6 1 15 4 6 10 3 0 5 1 5 NA 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 100 000 2 Pipe or 2 In Concentric 2 38 11 6 33 10 1 28 8 5 23 7 0 18 5 5 13 4 0 2 1 2 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 120 000 2 Pipe or 3 In Concentri...

Page 16: ...51 15 5 46 14 0 41 12 5 100 000 2 Pipe or 2 In Concentric 2 24 7 3 19 5 8 14 4 3 9 2 7 NA NA 2 1 2 57 17 4 55 16 8 53 16 2 51 15 5 49 14 9 47 14 3 120 000 2 Pipe or 3 In Concentric 3 one disk 39 11 9 37 11 3 35 10 7 33 10 1 31 9 5 29 8 8 Disk usage Unless otherwise stated use perforated disk assembly factory supplied in loose parts bag Wide radius elbow Vent sizing for Canadian installations over ...

Page 17: ...140 taille sont pour altitudes comprises entre 0 2 135m 0 7 000 pi Utiliser une trousse de conversion fournie par le fabricant pour passer au gaz propane ou pour certaines installations au gaznaturel Cette fournaise à air pulsé est pour installation à l intérieur dans un bâtiment construit sur place Cette fournaise à air pulsé peut être installée dans une maison préfabriquée maison mobile si presc...

Page 18: ...ER GAS FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE A06511 Upflow Application ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR DIRECT VENT 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A07799 Downflow Application 58MVC ...

Page 19: ...PIPE APPLICATION OPTIONAL VENTILATED COMBUSTION AIR APPLICATION A07800 Attic Horizontal Application COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION VENT PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN AIRFLOW AIR CONDITIONING COIL REFRIGERATION PIPING FRONT OF FURNACE OPTIONAL VENTILATED COMBUSTION AIR INTAKE A07801 Crawlspace Horizontal Application 58MVC ...

Page 20: ...vibration transmission Primary Heat Exchangers Primary heat exchangers shall be 3 Pass 20 gauge corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a flow through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with f...

Reviews: