8
2-1/2-in.
(64.4)
1-1/4-in.
(31.8)
A11405
Fig. 6 -- Igniter Position -- Back View
2 − in.
(2.5 mm
3/8 − in.
3/16− in.
, +0.8 -1.5)
(50 mm)
(9.6 mm)
(4.6 mm)
3/32 − in., +1/32 -3/64-in.
A12392
Fig. 7 -- Igniter Position -- Side View
CONVERT GAS VALVE
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Gas supply MUST be shut off before disconnecting
electrical power and proceeding with conversion.
!
WARNING
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow this warning could result in personal
injury, death or property damage.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag. There may be more than one
disconnect switch. Lock out and tag switch with a suitable
warning label. Verify proper operation after servicing.
!
WARNING
Refer to Fig. 8 and 9.
A11373
Fig. 8 -- Propane Jumper
A11502
Fig. 9 -- Removing Propane Jumper
NOTE
: The Propane jumper for the modulating gas valve is
very small. Needle-nose pliers are required to remove the jumper
from the gas valve.
1. Locate the round
“LP GAS”
sticker on the top of the gas
valve.
2. Peel the sticker off and discard.
3. Note the small square opening in the top of the gas valve.
4. Remove the small black plastic Propane jumper from the
gas valve.
5. Cover the opening in the gas valve with a small piece of
black electrical tape.
REMOVE LOW GAS PRESSURE SWITCH
NOTE
: There are 2 ways that the Low Gas Pressure Switch
(LGPS) could have been installed during the original natural to
Propane gas conversion.
All 14 3/16-in. (360 mm) Casings or Vent Passes Between
Inducer Assembly and Burner Assembly
If the vent pipe passes between the inducer and burner assembly,
or the furnace is a 14 3/16-in. (360 mm) wide casing, the switch
may have been installed as follows. (See Fig 10.)
1. Remove low gas pressure switch, brass street 90
_
elbow,
brass Hex nipple, brass tee and black iron street 90
_
elbow
from the gas valve inlet pressure tap. (See Fig 10.)