background image

5

INSTALL SHELVES

Product shelves and a bag containing shelf support 

clips are packed inside the unit. Refer to Table 1 to 

verify quantity of shelves and shelf supporting clips.  

Bottom shelf must be placed on interior floor and 

should be inserted into the two retainer clips provided 

at the rear corners of the unit floor.

„

TO INSTALL SHELVES

 — Refer to Figures 5 and 6.

1. Determine proper location for shelf clips. Refer to 

the numbers on the pilaster to ensure that all 

clips are properly located.

2. Insert top tab of the shelf clip into the desired hole 

of the pilaster. The retaining tab should be facing 

upward as shown in Figure 5.

3. Rotate the clip downward and insert the bottom 

tab into the appropriate hole on the pilaster.

If necessary, squeeze the clip slightly during 

installation.

4. Install all remaining clips as described above.
5. Install shelves onto clips so that the product 

retention bar is facing upward. Be careful not to 

dislodge clips during shelf installation.

6. Shelves must be placed so that the retaining tab 

on the shelf clip captures the shelf as shown in 

Figure 6.

7. Before loading the shelf, ensure that the shelf is 

resting on each of 4 clips and that the clips are 

installed as shown in Figures 5 and 6.

CONDENSATE DISPOSAL

The evaporator drain pan is located in the base of the 

cartridge. Airflow in cartridge compartment hastens 

condensate evaporation so that external drain plumb-

ing is not required.

Improper shelf clip installation may cause shelf and/

or product to fall which could result in personal 

injury or damage to the unit.

Do not overload the shelves. The unit is designed to 

use all the shelves provided, installed in equally 

spaced configuration. Failure to install shelves cor-

rectly could result in personal injury or damage to 

the unit. If fewer shelves or a different installation 

configuration is desired, contact the manufacturer to 

ensure that shelf overloading will not occur.

PRODUCT
RETENTION BAR

SHELF 
RETAINED
BY TAB

PILASTER

TOP TAB
FULLY INSERTED
INTO SLOT

BOTTOM TAB
FULLY SEATED

IMPROPERLY INSTALLED
CLIP (UPSIDE DOWN)

   

      

RETAINING TAB

SHELF CLIP

TOP TAB

BOTTOM TAB

PROPERLY INSTALLED CLIP

FIGURE 5 — SHELF CLIP INSTALLATION

FIGURE 6 — PROPER INSTALLATION OF

SHELF ON CLIP

a79-5

a79-6

Summary of Contents for Miracool 1300L

Page 1: ...hout notice and without incurring obligations Printed in Mexico 6 06 79BC560002 01_C OWNER S MANUAL MIRACOOL GLASS DOOR MERCHANDISER 260L 1300L 300L 750L 1300L a79 13 a79 14 a79 15 Sales Office P O Bo...

Page 2: ...ll accessories and components including legs casters and shelves File a claim immediately with the shipping company if shipment is damaged or incomplete INSTALLATION LOCATE UNIT Refer to Figure 1 for...

Page 3: ...PER LEFT CORNER FLUORESCENT LAMP SIGNBOARD SIZES 750L 1100L AND 1300L ONLY WOOD SKID RETAINING SCREW IF USED HEX HEAD BOLT SCREW POWER CORD LEFT CONNECTOR LIGHTING CORD RIGHT CONNECTOR CARTRIDGE COMPA...

Page 4: ...ree Use caution to ensure that power and electrical cords do not get pinched between the cartridge and cabinet while removing cartridge TO LEVEL UNIT The door is equipped with gravity assisted cams an...

Page 5: ...retaining tab on the shelf clip captures the shelf as shown in Figure 6 7 Before loading the shelf ensure that the shelf is resting on each of 4 clips and that the clips are installed as shown in Figu...

Page 6: ...he lamp holder Refer to Figure 7 On units with safety shields the identification mark cannot be seen See Figure 8 Verify manually that the lamp has been rotated and locked into place Improperly instal...

Page 7: ...igher setting Adjust tempera ture control in small increments one position at a time NOTE For operation above 3 000 ft altitude ther mostat should be adjusted by a qualified service technician Before...

Page 8: ...r disconnecting the unit from the power supply remove the grille retaining screw located in the upper most part of the grille See Figure 1 2 Lift the grille up and away from the unit 3 Unplug the powe...

Page 9: ...itrogen Use care to purge air from the charging hose when breaking the vacuum CHARGING REFRIGERATION SYSTEM Refer to Table 2 for refrigerant type and amount of charge Since capillary tube systems have...

Page 10: ...lace 5 Excessive discharge pressure 5 Check ventilation restrictions in cooling medium restrictions in refrigeration system 6 Compressor too hot return gas hot 6 Check refrigerant charge fix leak if n...

Page 11: ...11 FIGURE 10 WIRING DIAGRAM SIZES 260L 300L a79 10...

Page 12: ...12 a79 12 FIGURE 11 WIRING DIAGRAM SIZE 750L...

Page 13: ...13 FIGURE 12 WIRING DIAGRAM SIZES 1100L 1300L a79 11...

Page 14: ...can be used to remove debris CABINET EXTERIOR Cabinets should be cleaned with a solution of mild soap and water or mild household cleaner Do not use caustic soap or abrasive cleaners since these might...

Page 15: ...Sponge with cloth then rinse with clear water and wipe dry Satisfactory for use on all finishes Stubborn Spots and Stains Caked on Splatter and other Light Discolorations Revere Ware Goddard s Twinkl...

Page 16: ...2006 Carrier Corporation Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Printed in Mexico 6 06 79BC560...

Reviews: