11
62-12119
14.
Remove or Open Exterior Panels
.
15.
Leak Checking
.
a. Examine the unit for traces of oil residue. Leak check the unit
using an electronic leak detector. Leaks are typically found as
a dirty / oily residue near the leak location. All mechanical
joints to be leak tested can be found in the
. Repair
as required and clean the unit using low pressure water.
16.
Corrosion
.
Perform on-going corrosion maintenance if corrosion found on
any painted surface. Perform these steps:
a. Remove loose corrosion material.
b. Lightly scuff up the surface with a Scotch-Brite Heavy Duty
Scour Pad (or similar).
c. Wipe down with isopropyl alcohol to remove loose material
and any grease.
d. Paint using the following standard paint specifications (pur
-
chase locally).
17.
Access Panels
.
a. Remove the left and right hand evaporator access panels.
b. Check that the access panel seals are present and in good
condition to provide a good seal.
c. Check for excessive shaft end play on the evaporator motor.
d. Replace panels on completion assuring all hardware (includ
-
ing the Mylar washer) is installed.
e. When reinstalling the panels, use a torque setting of 60 +5 in-
lbs. (6.8 N-M) and the pattern shown in
Figure 11 Access Panels
Part
Color
Brand
Paint
Compressor /
Flash Tank
Grey
DNT
V-TOP #188
Frame
White Cloud
Rust-Oleum
9100 System