Table 7: Technical Specifications
LOWBOY SERIES 098
Firing rate (USGPH)*
0,55
0,70
0,55
0,70
Input (BTU/h)*
77 000
98 000
77 000
98 000
Maximum Heating capacity, (BTU/h)*
65 000
81 000
65 000
81 000
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL AFG (Chimney)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.50 - 60A
0.60 - 60W
0.50 - 60A
0.60 - 60W
Pump pressure (PSIG)*
150
140
150
140
Head/Air setting
3,0
3,5
3,0
3,5
AFUE % (From CSA B212 standard and Canadian regulation)***
86,9%
86,4%
86,9% ‡
86,4% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
85,7%
85,1%
85,7% ‡
85,1% ‡
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.50 - 60W
0.60 - 60W
0.60 - 60W
0.65 - 60W
Pump pressure (PSIG)*
150
140
140
150
Head/Air setting
3,0
3,5
3,0
3,5
AFUE % (From CSA B212 standard and Canadian regulation)***
87,9%
86,3%
87,9% ‡
86,3% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
86,9%
85.2%
86,9% ‡
85.2% ‡
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.50 - 70A
0.60 - 70A
0.50 - 70A
0.60 - 70A
Pump pressure (PSIG)*
150
140
150
140
Combustion air adjustment (turbulator/damper)
0 / 2.0
1 / 3.5
0 / 2.0
1 / 3.5
AFUE % (From CSA B212 standard and Canadian regulation)***
87,6%
86,3%
87,6% ‡
86,3% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
86.6%
85,2%
86.6% ‡
85,2% ‡
RIELLO BURNER; MODEL 40-BF3 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.50 - 70A
0.60 - 70A
0.50 - 70A
0.60 - 70A
Pump pressure (PSIG)*
150
140
150
140
Combustion air adjustment (turbulator/damper)
0 / 3,5
1 / 5.25
0 / 3,5
1 / 5.25
AFUE % (From CSA B212 standard and Canadian regulation)***
87,1%
85,4%
87,1% ‡
85,4% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
86,7%
85,0%
86,7% ‡
85,0% ‡
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available Heating (VA)
Cooling (VA)
Heating blower speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
Heating blower speed at 0.50" W.C. SP
MED-LOW
HIGH
Motor (HP) / number of speeds
Blower size (diam. x width)
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size and quantity
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
Note 1:
With Low firing baffle # 3708
Note 2:
With Low firing baffle # 32229
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Adjust flue gas temperature between 400˚ and 575˚F.
- Adjust fan speed for the air temperature rise specified.
** Default Installed Nozzle in bold characters
*** AFUE value established after minimum 20 hours of operation.
175 Lbs / 80 Kg
175 Lbs / 80 Kg
3,0
3,0
18'' x 20''
18'' x 20''
20'' x 20'' x 1" ou 2''
20'' x 20'' x 1" ou 2''
GENERAL INFORMATION
21'' x 47'' x 34''
21'' x 47'' x 34''
20'' x 20''
20'' x 20''
1/3 HP / 4 speed
1/2 HP / ECM
10'' x 10'' (tight housing)
10'' x 10'' (tight housing)
30
30
BLOWER DATA
See the ECM air flow table
40
40
40
40
13,7
12,2
15
15
ELECTRICAL SYSTEM
115 - 60 - 1
115 - 60 - 1
12,2
10,3
BF3
BF3
2 3/4''
2 3/4''
F3 WITH AIR INLET DAMPER
F3 WITH AIR INLET DAMPER
2 3/4''
2 3/4''
1 3/4''
1 3/4''
6 - Slot LQ Head
6 - Slot LQ Head
2 - Slot L2 Head
2 - Slot L2 Head
NX56LQ (Note 2)
NX56LQ (Note 2)
AFG70MQSS (Note 1)
AFG70MQSS (Note 1)
1 3/4''
1 3/4''
+0.03 à +0.20
+0.03 à +0.20
+0.05 à +0.15
+0.05 à +0.15
-0.06 à -0.025
-0.06 à -0.025
-0.035 à +0.010
-0.035 à +0.010
UNITS WITH 1/3 HP 4-SPD. MOTOR
UNITS WITH 1/2 HP ECM MOTOR
RATING AND PERFORMANCE
55 - 85 Degr. F
55 - 85 Degr. F
‡ =
Summary of Contents for OBL098
Page 16: ...16 Figure 6 Furnace Dimensions ...
Page 17: ...17 Figure 7 Wiring Diagram 4 Speed Motor PSC ...
Page 18: ...18 Figure 8 Wiring Diagram Variable Speed Motor ECM ...
Page 19: ...19 Figure 9 Parts List With 4 Speed motor PSC B50082E ...
Page 21: ...21 Figure 10 Parts List With variable speed motor ECM B50083E ...
Page 23: ......
Page 24: ......
Page 29: ...Figure 8 Diagramme électrique Moteur vitesse variable ECM 20 ...