15
Table 9: Airflow Data, Models with 1/3 HP PSC motors
0.2 " (W .C.)
0 .3" (W . C. )
0. 4" (W .C.)
0.5 " (W .C.)
0 .6" (W .C. )
0. 7" (W .C.)
HIGH
14 20
1 33 5
12 40
11 80
1 08 5
10 25
M E D-HIGH
12 75
1 23 0
11 70
10 95
1 04 5
9 60
M ED-LOW
10 15
1 00 0
9 55
91 5
8 60
7 85
LO W
81 5
785
7 75
73 0
6 90
6 35
S PEE D
AMT098
EX TERNAL S TATIC PRE SSURE WI TH AIR FI LTE R
Table 10:Minimum clearances from combustible material
LOCATIO N
APP LICATIO N
CLEARANCE S
(c om bustible
m ateri als )
RE COM MANDED
ACCES S FOR
SERV ICE
FURNA CE
1 "
24 "
SUP PL Y P LE NUM W ITHIN 6 FEE T OF FURNACE
1 "
BACK
ACCES S PANE L TO BL OW ER
4 "
24 "
FURNA CE OR PLE NUM
2 "
HORIZONTAL W A RM A IR DUCT WI THI N 6 FEE T OF FURNACE
2 "
BO TTOM
FURNA CE (COM BUSTIB LE FLO OR)
0 "
FLUE PI PE
ARO UND FL UE PI PE
9 "
FRO NT
FURNA CE
8 "
24 "
TO P
SIDES
Summary of Contents for OBL098