background image

Operation and Maintenance Manual

NOTE: 

Read all instructions and data in this manual before operating.

A200220

Fig. 1 – FN1AAF

A Note About Safety

Any time you see this symbol   in manuals, instructions and on  the

unit, be aware of the potential for personal injury. There are three levels

of precaution:

DANGER

 identifies the most serious hazards which will result in severe

personal injury or death. 

WARNING

  signifies  hazards  that  could  result  in  personal  injury  or

death. 

CAUTION

 is used to  identify unsafe practices which  would  result in

minor personal injury or product and property damage.

NOTE

 is  used to  highlight suggestions  which  will  result in  enhanced

installation, reliability, or operation.

About Your Negative Air Machine

The OptiClean™ negative air machine is a portable solution primarily

designed to help convert normal hospital rooms into Airborne Infectious

Isolation  Rooms  (AIIR).  Designed  to  ASHRAE’s  Standard  170  for

Ventilation  of  Health  Care  Facilities,  the  OptiClean™  uses  highly

efficient  filters  and  a  heavy  duty,  yet  quiet,  motor  to  remove

contaminated air from the room. The resulting negative air pressure, or

“vacuum effect,” helps limit the spread of air-based contaminants into

surrounding  areas.  If  negative  pressure  is  not  required,  such  as  in  an

open-air,  temporary  hospital,  the  machine  can  be  used  as  an  air

“scrubber,” pulling air in, removing many contaminants, and discharging

cleaner air back into the room.
The OptiClean™ negative air machine features:
• 99.97% efficient long-life HEPA filter removes particles as small as

0.3 microns

• Standard MERV 7 or higher pre-filter
• Minimum 500 CFM and Maximum 1500 CFM
• Meets or exceeds ASHRAE Standard 170: Ventilation of Health Care

Facilities

• Vertical design for smaller footprint compared to many competitors,

and can be mounted and operated horizontally when necessary

• Portable and adaptable to nearly any location
• Heavy duty locking casters for easy and smooth transport
• HEPA filter rack and sealing design meet air leakage requirement
• Red  lighted  indicator  to  alert  user  when  filters  are  overloaded

(generally means pre-filter requires replacement)

• Green ON/OFF switch illuminates to verify when running
• 3-speed selector switch on 015 size model for various air flow ranges
• 10-foot long power cord with strain relief
• 115V
• Galvanized steel, pre-painted cabinet is fully insulated
• Exhaust  transition  plate  to  standard  10-inch  round  (005  size)  or

12-inch oval (015 size) duct included

• UL® Listed
• One year limited warranty
• Currently designed for commercial applications only

UL and the UL logo are trademarks of UL LLC.

FN1AAF

OptiClean™ Negative Air Machine and Scrubber

WARNING

!

PERSONAL INJURY OR PROPERTY DAMAGE 

HAZARD 

Failure  to  follow  this  warning  could  result  in  personal  injury  or

property damage.

Improper  installation, adjustment, alteration, service,  maintenance,  or

use can cause conditions which may cause personal injury or property

damage. Consult a qualified installer or your distributor for information

or assistance. Read and follow all instructions and warnings, including

labels shipped with or attached to unit before operating.

015 SIZE

WARNING

!

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Disconnect  all  electrical  power  to  the  unit  before  removing  access

panels to perform any maintenance.

Summary of Contents for OptiClean FN1AAF 005

Page 1: ...rd MERV 7 or higher pre filter Minimum 500 CFM and Maximum 1500 CFM Meets or exceeds ASHRAE Standard 170 Ventilation of Health Care Facilities Vertical design for smaller footprint compared to many competitors and can be mounted and operated horizontally when necessary Portable and adaptable to nearly any location Heavy duty locking casters for easy and smooth transport HEPA filter rack and sealin...

Page 2: ... Remove the bottom front door then the top door over the blower section Inspect the HEPA filter and make sure it has not been dislodged or damaged during shipping that the side bolts and nuts near each corner are tight and the HEPA filter is held securely in place and the seal around the top edge of the filter is in place 9 Make sure the first stage pre filter is in place and not damaged 10 Replac...

Page 3: ...se a 1 2 inch open end or adjustable wrench to remove the bottom nuts from the all thread bars on both sides four nuts total 7 Slide the bottom HEPA filter supports down along with the filter and out of the unit 8 Remove the HEPA filter and immediately put it inside an approved containment bag Dispose per facility guidelines for hazardous materials 9 Position the new HEPA filter into the unit with...

Page 4: ...ting and or repairs be sure to have the model and serial numbers of your equipment available Specifications A200223 Fig 7 005 Model Wiring Diagram A200258 Fig 8 015 Model Wiring Diagram Switch Setting Motor Lead Motor Tap Options LOW Red 1 2 3 Switch Setting Motor Lead Motor Tap Options MED Blue 2 3 4 Switch Setting Motor Lead Motor Tap Options HIGH Gray 5 Table 2 Electrical Specifications 005 Mod...

Page 5: ...103 342890 75105 6 2 Gasket 6 152 mm 346295 402 7 2 Gasket 16 408 mm or 20 506 mm 346295 401 346295 403 8 2 Caster Assembly 346285 701 346285 702 9 1 HEPA Filter 346345 75101 346345 75102 10 1 Pre filter MERV 7 KH01AZ500 KH01AZ501 11 1 Lower Door Assembly 346279 701 346279 702 12 1 Upper Door Assembly 346277 701 346277 702 13 1 Indicator red 346299 401 14 1 Power Switch green lighted 346300 401 15...

Page 6: ...dition Date 06 20 Catalog No OM FN1AAF 02 Replaces OM FN1AAF 01 FN1AAF Operation and Maintenance Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 6 Notes Page ...

Reviews: