14
A150225
6.
If no key is pressed for 3 minutes, the configuration mode will auto-
matically exit, returning the thermostat to normal operation.
Option 01 - Equipment type
You may need to make an adjustment to this setting depending on the system
you've connected. If you're unsure about your system type, refer to wiring
diagrams beginning on page 23.
Options: HP, H2, AC, A2, H, C
Description:
S
HP controls 1 speed heat pump with 1 stage of auxiliary heat.
S
A2 controls two stages of cooling and one stage of furnace heat.
S
H2 controls a 2 Speed HP with 1 stage of auxiliary heat.
S
AC controls 1 speed air conditioner with 1 stage of heat.
S
H operates a heat only system: furnace or fan coil only; no outdoor unit.
S
C operates a cool only system: outdoor AC unit with an indoor fan coil; no
strip heater support.
Option 03 - Fahrenheit/Centigrade
Default: Fahrenheit (F)
Selections: Fahrenheit (F), Centigrade (C)