19
example, a temperature setting when you’re home and a different
temperature setting when you sleep.
S
Selecting 4 allows 4 programming periods per day, P1, P2, P3, and P4.
For example, different temperature settings when you’re waking up, away,
at home, and sleeping.
Option 26 - Minimum Cooling Setpoint
Default: 52°F
Options: Between 52°F and 90°F
'Description: Sets the lowest cooling setpoint available.
Option 27 - Maximum Heating Setpoint
Default: 88°F
Options: Between 50°F and 88°F
Description: Sets the highest heating setpoint available.
Option 99 - Reset to Factory Defaults
Use this capability to reset the thermostat to “out of the box” conditions.
When this option is selected, the configuration number (99), will appear on the
left and 10 will appear on the right. To perform the reset, first use the MODE
key to make the 10 flash. Then press and hold the DOWN key. The 10 will
start counting down toward zero. If the DOWN key is kept pressed until the
count reaches zero, the reset will be performed. If the DOWN key is released
early, the number will return to 10 and the reset will not occur.
NOTE
:
All configuration settings, program settings, clock, and day which
have been manually entered will be lost!