If Cool to Dehumidify is disabled, you will get the following operation:
4) Congratulations, you have now set-up the system for dehumidification.
Furnace Dehumidification with 58DLA/DLX, 58CTA/58CTX Models
These furnaces are equipped with the Dehum terminal on the control board. However;
they are equipped with PSC motors. These motors do not hold CFM with high static
like the ECM motors. Therefore, it is critical to get the blower motor speed taps correct.
See furnace installation for motor performance.
Some places with very low humidity like to run AC units at high airflow. This high
airflow limits the amount of moisture removed by the air conditioner. Under most
conditions, this is o.k. However; sometimes when people are boiling water, etc.
humidity can become an issue. This furnace allows you to run high airflow when no
moisture removal is preferred and normal or lower airflow under high humidity
conditions.
Setup and operation sequence for this furnace is the same as the setup for the
Performance furnace. Follow those instructions once speed tap selections are chosen.