6.16 Abnormal Temperatures
High discharge temperature
Condenser coil dirty
Condenser fan rotating backwards
Condenser fan inoperative
Refrigerant overcharge or non-condensibles
Discharge service valve partially closed
Open
Electronic expansion valve (EEV) control malfunction Replace
Failed suction pressure transducer (SPT) or evapora
-
tor pressure transducer (EPT)
Replace
Discharge temperature sensor drifting high
Replace
Failed economizer expansion valve (EXV), econo
-
mizer coil, or economizer solenoid valve (ESV)
Replace
Plugged economizer expansion valve (EXV), econo
-
mizer coil, or economizer solenoid valve (ESV)
Replace
Loose or insufficiently clamped sensor
Replace