T-340
7–28
d. Procedure for Setting the Container ID:
NOTE
The characters will be preset to the container ID already on the controller. If none exist, the default will be
AAAA0000000.
1. Press the Up or Down Arrow key until display reads Set ID.
2. Press the ENTER key on the keypad.
3. Values will be entered from right to left. Press the Up or Down Arrow key to increase or decrease the values.
ENTER will enter the information for the current field and move to the next value; CODE SELECT will allow
modification of the previous value.
4. When the last value is entered, press the ENTER key to enter the information to the controller; the CODE
SELECT key will allow modification of the previous value.
7.23.4
Removing and Installing a Controller
Removal:
1. Disconnect all front wire harness connectors and move wiring out of way.
2. The lower controller mounting is slotted, loosen the top mounting screw (see
) and lift up and out.
3. Disconnect the back connectors and remove module.
4. When removing the replacement module from its packaging, note how it is packaged.When returning the old
module for service, place it in the packaging in the same manner as the replacement. The packaging has
been designed to protect the module from both physical and electrostatic discharge damage during storage
and transit.
Installation:
1. Install the module by reversing the removal steps.
2. Torque values for mounting screws (item 2, see
) are 0.23 mkg (20 inch-pounds). Torque value
for the connectors is 0.12 mkg (10 inch-pounds).
7.23.5
Battery Replacement
Standard Battery Location (Standard Cells):
1. Turn unit power OFF and disconnect power supply.
2. Slide bracket out and remove old batteries (see
, Item 8.)
3. Install new batteries and slide bracket into control box slot.
CAUTION
!
Use care when cutting wire ties to avoid nicking or cutting wires.
Standard Battery Location (Rechargeable Cells):
1. Turn unit power OFF and disconnect power supply.
2. Disconnect battery wire connector from control box.
3. Slide out and remove old battery and bracket (see
, Item 8.)
4. Slide new battery pack and bracket into the control box slot.
5. Reconnect battery wire connector to control box and replace wire ties that were removed.
Secure Battery Option (Rechargeable Cells Only):
1. Turn unit power OFF and disconnect power supply.
2. Open control box door and remove both the high voltage shield and clear plastic rain shield (if installed).