NOTICE
If using the Electronic Partlow Recorder CTD part number 12-00464-xx,
Where xx= an even number (example: 12-00464-08)
The recorder will STOP when the power is OFF, and the pen tip will remain at the last recorded temperature on the
chart. When power is applied, and the power off period is less than thirty days, the recorder will retrieve the logged
data from the DataCORDER for the power off period and record it onto the chart. Thereafter, the recorder will
resume normal temperature recording.
If the optional DataCORDER battery pack is being used and the charge is too low to enable recording during the
power off period of less than thirty days, the pen tip will move to below the inner chart ring for the period when NO
data was recorded by the DataCORDER.
7.28.1
Replacing the Recorder
1. Turn power to the unit OFF.
2. Open the recorder door (item 1, see
).
3. Locate the connector below the recorder (item 6), and squeeze the ears together to disconnect the plug.
4. Remove the four mounting screws (item 8), and remove the recorder.
5. Install the new recorder by reversing the above steps.
Figure 7.26 Electronic Partlow Temperature Recorder
1) Recorder Door
2) Change Chart Button
3) Recorder Box
4) Pen Tip
5) Stylus Arm
6) Connector
7) Calibration Button (Located underneath)
8) Mounting Screws, #10-24 x 7/16 inches long
9) Hold Down Tab
10) Chart Retaining Nut
- - - - -