T-340
6–4
6.9 Microprocessor Malfunction
Will not control
Incorrect software and / or controller configuration
Check
Defective sensor
Defective wiring
Check
Low refrigerant charge
6.10 No Evaporator Air Flow Or Restricted Air Flow
Evaporator coil blocked
Frost on coil
Dirty coil
No or partial evaporator
air flow
Evaporator fan motor internal protector open
Evaporator fan motor(s) defective
Evaporator fan(s) loose or defective
Evaporator fan contactor defective
Replace
6.11 eAutoFresh Not Operating
Vent not opening
Unit not configured for eAutoFresh Operation
No action
Cd43 in OFF mode
Wiring disconnected
Check wiring
Stepper drive defective
Stepper motor defective
Unit operating in frozen mode
Gas Limit mode unavailable
Check CO
2
sensor
Wiring disconnected
Check wiring
Unit operating in frozen mode
Unable to calibrate
CO
2
sensor
ENTER Key not held for sufficient length of time
CO
2
outside of acceptable levels
Check
Check CO
2
sensor
Code 44 displays “- - - - - “
Unit not configured for eAutoFresh Operation
No action
Check CO
2
sensor
6.12 Electronic Expansion Valve Malfunction
Low suction pressure
Incorrect software and / or controller configuration
Check
Failed suction pressure transducer (SPT) or evapora
-
tor pressure transducer (EPT)
Replace
Suction service valve partially closed
Open
Filter drier partially plugged
Low refrigerant charge
No evaporator air flow or restricted air flow
Excessive frost on evaporator coil
Evaporator fan(s) rotating backwards
Electronic expansion valve (EEV) control malfunction
Failed digital unloader valve (DUV)
Loose or insufficiently clamped sensor
Replace
Condition
Possible Cause
Remedy / Reference