• If a suspected malfunction occurs with your gas control 
system, such as the burners not lighting when they should, 
refer to the shutdown procedures on the furnace, or in the 
section, “Shutting Down Your Furnace” and call your dealer 
as soon as possible.

 

CHECK AIR FILTER:

 

 Before attempting to start your fur-

nace, be sure the furnace filter is clean and in place. See sec-
tion “Performing Routine Maintenance” in this manual. 
Then proceed as follows:

 

STEPS FOR STARTING YOUR FURNACE

 

1. Set your room thermostat to the lowest temperature 

setting. (See Fig. 8.)

2. Close the external manual gas valve. (See Fig. 9.)

3. Turn off electrical supply to the furnace. (See Fig. 10.)

 

8

9

 

4. Remove the furnace access door. (See Fig. 11.)

5. Turn control knob on the gas valve to the OFF position 

and wait 5 minutes. Then smell for gas, including near 
the floor. If you smell gas, 

 

STOP!

 

 Follow operating 

instructions on furnace access door. (See Fig. 12.)

6. After waiting 5 minutes, turn control knob on the gas 

valve to the ON position. (See Fig. 12.)

7. Replace furnace access door. (See Fig. 13.)

8. Turn on electrical supply to the furnace and wait 

1 minute. (See Fig. 14.)

9. Open the external manual gas valve. (See Fig. 15.)

10. Set room thermostat to a temperature slightly above

room temperature. This will automatically signal the 
furnace to start.

 11. When the furnace receives the start signal, the hot sur-

face ignitor at the main burners is automatically heated 
for 15 to 20 sec. When the microprocessor control ver-
ifies that there is sufficient heat to ignite, the gas valve 
permits gas to flow to the main burners. After ignition 
and a time delay of about 35 sec, your blower will start 
at low speed until the control makes the necessary 
adjustments to operate the blower at either the low- or 
high-fire speed.

 

WARNING

 

If overheating occurs or the gas valve fails to shut
off the gas supply, turn off  the manual gas valve
to the furnace BEFORE turning off the electrical
supply. (See Fig. 9.) Failure to follow this warning
could result in a fire or explosion, and personal in-
jury or death.

 

!

 

SYSTEM

COOL OFF HEAT

FAN

AUTO

ON

50

70

90

50

70

90

 

CL

O

S

E

10

11

12

 

NOTE:

 

 If the burners fail to ignite after 4 attempts, the fur-

nace control system will lockout. If lockout occurs, main 
burners fail to light, or blower does not come on, shut down 
the furnace and call your dealer for service.

 

13

14

15

 

 12. Set your thermostat to the temperature that satisfies 

your comfort requirements. SUGGESTION: Setting 
the thermostat back a few degrees and compensating 
for the difference with warmer clothing can make a big 
difference in your fuel consumption on extremely cold 
days. The few degrees at the top of your thermostat 
“comfort level” are the most costly degrees to obtain.

  

FF

O

  

OP

E

N

Summary of Contents for Weathermaker 9200

Page 1: ...ot use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier HEATING COOLING MULTIPOISE CONDENSING 58MCA 58MVP 58MXA USER S INFORMATION MANUAL FOR THE OPERATION AN...

Page 2: ...epend able We are proud of the technological advances incorpo rated into the design of these furnaces With only minimal care your new furnace will deliver many years of money saving home comfort and enjoyment Spend just a few min utes with this manual to learn the operation of your new fur nace and the small amount of maintenance it takes to help keep it operating at peak efficiency year after yea...

Page 3: ...anger inside Wrings out more heat through condensation Constructed with Polypropylene laminated steel to ensure durability Primary serpentine heat exchanger inside Stretches fuel dollars with the S shaped heat flow design Solid construction of corrosion resistant aluminized steel means reliability Control center 3 amp fuse provides electrical and component protection Light emitting diode LED on co...

Page 4: ...TY CONSIDERATIONS Installation and service of heating equipment can be hazard ous due to gas and electrical components Only trained and qualified personnel should install repair or service heating equipment Untrained personnel can perform basic maintenance func tions such as cleaning and replacing air filters All other oper ations must be performed by trained service personnel Observe safety preca...

Page 5: ...cally signal the furnace to start 11 When the furnace receives the start signal the hot sur face ignitor at the main burners is automatically heated for 15 to 20 sec When the microprocessor control ver ifies that there is sufficient heat to ignite the gas valve permits gas to flow to the main burners After ignition and a time delay of about 35 sec your blower will start at low speed until the cont...

Page 6: ...pied structure during winter See winterizing proce dures in maintenance section SYSTEM COOL OFF HEAT FAN AUTO ON 50 70 90 50 70 90 18 FILTERING OUT TROUBLE A dirty filter will cause a loss of airflow in your duct system When excessive loss of airflow occurs the furnace may cycle on the safety controls If this condition is left unat tended the furnace will eventually lockout It is recom mended that...

Page 7: ...on Make sure that all PVC pipes leading into the combustion area and vent are free from any cracks and sags Also check the combustion air intake and vent pipes on the outside of your home for blockage When dirt soot scale or rust is allowed to build up your furnace can suffer a loss of efficiency and perform improp erly Accumulations on the main burners can result in firing out of normal sequence ...

Page 8: ...drain connection cap See Fig 30 5 Connect field supplied 1 2 in ID tube to upper inducer housing drain connection 6 Insert field supplied funnel into tube 7 Pour 1 quart of antifreeze into funnel tube Antifreeze should run through inducer housing overfill conden sate trap and flow into open field drain See Fig 31 8 Remove funnel and tube from inducer housing and replace drain connection cap and cl...

Page 9: ...uctions around the vent termination If the furnace still fails to operate call your service representative For your convenience record the furnace product and serial numbers on page 2 Should you ever require service you will have ready access to the information needed by your service representative This furnace has an LED operation and fault code display to aid the installer service technician or ...

Page 10: ...ermostat switch to call for heat 13 or 33 Limit Switch Lockout 14 or 34 Ignition Lockout or Ignition Proving Fault M Check to be sure manual shut off valve in gas supply pipe is in open position Follow start up procedure if you open gas line NOTE Turn off the electrical supply and remove access doors before continuing with this checklist M Check to be sure control knob on gas valve is in ON positi...

Reviews: