Appendix A - Smart-Frame Protocol Command Reference
CARROLL TOUCH
A-20
Touch System Programmer’s Guide
Sa, ..., Sn
=
Status of failed y-beams; has the same values (0-4) and
definitions as status of failed x-beams.
FF
=
End of report.
Example
An example of a Failed Beam Report is:
FA 01 03 02 00 FF
It indicates that there is one failed x-beam (beam number 3), that its
LED failed, and that there are no failed y-beams.