Carron Revolution 5kw

INSTALLATION INSTRUCTIONS

150mm

600mm

550mm

Combustible Material

Combu

sti

ble 

Ma

teri

al

Combu

sti

ble 
Ma
teri
al

Installation Clearances

Minimum clearance to 
combustibles

Above the appliance - 600mm
Each Side of the appliance – 550mm
Rear of the appliance – 600mm

Minimum clearance to 
non-combustibles

Above the appliance - 300mm
Each Side of the appliance – 150mm
Rear of the appliance – 150mm (this 
can be reduced to 50mm if the wall 
thickness is greater than 200mm)

150mm

300mm

Failure to adhere to these clearance will invalidate the warranty 

and could damage your appliance/property.

Hearth Requirements

Place the stove on a solid non-combustible hearth extending 300mm at the front of the stove, 
150mm either side of the stove and 50mm at the rear. The hearth must have a thickness of at least 
12mm. The maximum hearth temperature attained during testing was 52.2°C (Refer to document J of 
the UK Building Regulations). Ensure that the floor has sufficient load bearing capacity. Fit a load 
bearing plate if necessary.

Flue Requirements

To ensure that your chimney meets the required 
specifications it must: -

be at least 5 metres high - have no bends 
sharper than 45 degrees

be swept clear of any obstructions by a 
qualified chimney sweep

terminate at least 1 metre above any roof 
ridge

have an internal cross-section of between 
0.018m2 and 0.14m2

be free from sources of leakage 

be connected only to the one appliance i.e. 
not a shared flue system 

be well insulated, or have a wall thickness of 
at least 100mm 

CO Alarms

In accordance with building regulations, a 
Carbon Monoxide Alarm, conforming to BS EN 
50292:2002 must be fitted in the same room 
whenever a new or replacement wood/solid 
fuel or biomass appliance is installed in a 
dwelling.

The alarm must be installed in accordance with 
the alarm manufacturers instructions and is 
not to be considered as an alternative to the 
appliance being installed correctly and 
subsequent regular maintenance of the 
appliance and associated flue system.  

Non

-C

omb

u

stib
le 

Ma
terial

Non-Combustible Material

Non

-C

omb

u

stib

le 

Ma

terial

Summary of Contents for CARRON REVOLUTION 5

Page 1: ...N AND OPERATION MANUAL MODEL CARRON REVOLUTION 5 Document REV Version 3 Dated 16th November 2018 Eco Design Ready Approved for use in Smoke Control Areas High Efficiency Cleanburn Modern Design External Air Supply ...

Page 2: ... a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are ...

Page 3: ...at the floor has sufficient load bearing capacity Fit a load bearing plate if necessary Flue Requirements To ensure that your chimney meets the required specifications it must be at least 5 metres high have no bends sharper than 45 degrees be swept clear of any obstructions by a qualified chimney sweep terminate at least 1 metre above any roof ridge have an internal cross section of between 0 018m...

Page 4: ...rience fumes and a light haze from the appliance as the paint cures during which you must ensure the room is well ventilated Normal Operation after initial firing To establish clean burning it is important to get the appliance hot as quickly as possible This can be achieved with the following ignition regime I Set the air control to the maximum setting by moving the air control to the right II Lig...

Page 5: ... suitable kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in the instructions Dampers left open Operation with the ...

Page 6: ...cted by a qualified person and any faults found have been rectified Persistent fume emission should not occur if the product is properly installed and operated However should this happen take immediate action as follows Ventilate the room Extinguish the fire Check the chimney flue for blockages and clean if required Seek expert advice if necessary Caution The stove and flue pipe will become extrem...

Page 7: ...nd the door glass to ensure this has not deteriorated or moved Flue to be swept annually by a competent person if in doubt contact a professional chimney sweep The stove is finished using a high temperature resistant coating which would normally last for many years Should the need arise to refinish refresh your appliance this can be done using a high temperature stove paint such as Hotspot If the ...

Page 8: ...is must never be removed in a Smoke Exempt Area Carron Revolution 5kw Flue Diameter 125mm 5 Flue Location Top or Rear Fuel Wood Nominal Output 5kw Total Efficiency 82 7 Mean flue gas temperature 253 C Flue Draft Required 12Pa Flue Mass Gas Flow 3 9g s Mean CO emission at 13 O2 0 08 Maximum Hearth Temperature Less than 100 C Weight 73kgs Maximum Log Size 300mm Length 125mm Width Construction Steel ...

Page 9: ... 0808 129 2224 INSTALLATION AND OPERATION MANUAL Carron Hurlingham Business Park Fulbeck Heath Grantham Lincolnshire NG32 3HL Email sales carron uk net Tel 0808 1292224 Spares available at www carronspares co uk ...

Reviews: