83
CARSON Reflex Stick Ultimate Touch 500501002
GB
Receiver connections explained
Binding
CH1-CH10: Connection to the relevant channel
(servo/ESC,etc.)
BIND, VCC: Connection for binding connector and
power supply.
OUT:
ASbus connection for outgoing PPMS
data signals and for connecting the
serial bus module to extend the
channels further.
IN:
Connection for all types of sensors.
The receiver supplied is already bound to the
transmitter. If you would like to bind a new receiver
to the system, please proceed as follows:
1. Install the battery in the transmitter and switch on
the remote control.
2 Open the main menu and select the “RX Set-up”
function on the second menu page and then press
“Bind with a receiver” to start the binding
procedure.
3. Insert the binding cable into the RX connection
“B/VCC”.
4. Connect a 6V battery to any channel from CH1 to
CH4. Ensure correct polarity. The receiver LED will
start to flash.
5.
The transmitter will end the bind mode
automatically once the receiver has been
successfully connected to the transmitter.
6. Unplug the binding cable and reconnect the
receiver to the battery. Please connect the servos
and sensors to the receiver and check all the
functions.
7. If the functions should fail to work properly, you
will need to repeat the above steps again.
Battery
Receiver
Bind cable