38
3327 • P2 6/06
AC ELECTRICAL SYSTEMS
SECTION 3
Water Heater
This breaker controls the flow of electricity to the water heater. The water heater
supplies hot water to your fresh water system. Switch this breaker “ON” to
supply power to the water heater. Refer to Section 4 - Fresh Water System for
more information.
Do not supply power to the water heater when it is empty. Doing so may
damage the unit’s heating element. Refer to Section 4 - Fresh Water
System to fill, pressurize and prime the fresh water system before
turning on the water heater.
Ground Fault Circuit Interrupters
When someone receives an electrical shock through a GFCI receptacle, the
current flowing to the receptacle continues flowing through the person’s body
and into any grounded object the person is touching or standing on. Thus, the
current does not return from the receptacle through the appropriate wire. The
GFCI “sees” this difference in current and shuts off power to the receptacle. This
limits the amount of time the person is being shocked to a brief moment, which
can reduce the amount of injury to the person.
Any electrical shock from the AC electrical system, even through a GFCI
receptacle, can cause death or serious injury. Always seek immediate
medical attention after receiving such a shock.
GFCI Receptacle Locations
Three GFCI receptacles are installed on the standard and mid cabin boat. Each
one protects a group of receptacles that can include both open outlets and those
that are already in use for built-in equipment. A GFCI receptacle is located:
• In the port aft corner of the salon, to protect the port receptacles, except for
those in the galley.
• In the galley above the trash container, to protect the galley receptacles.
• In the cockpit on the side of the starboard side deck stairway, to protect the
starboard receptacles.
GFCI RECEPTACLE LOCATIONS
Summary of Contents for 380 SPORT
Page 1: ...HIN CDR _________________ 380 Sport Owner s Guide 2007 Version 1 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 28: ......
Page 40: ...28 3327 P2 6 06 DC ELECTRICAL SYSTEM SECTION 2 DC SCHEMATIC 3327 324 002 5 12 7 05 ...
Page 54: ...42 3327 P2 6 06 AC ELECTRICAL SYSTEMS SECTION 3 AC SCHEMATIC 3327 300 015 2 9 04 ...
Page 108: ......
Page 122: ......
Page 124: ...112 3327 P2 6 06 WARRANTY AND PARTS SECTION 9 Hatches ...
Page 129: ...3327 P2 6 06 117 WARRANTY AND PARTS SECTION 9 Bill of Material ...
Page 130: ......
Page 131: ...3327 P2 6 06 119 WARRANTY AND PARTS SECTION 9 Carver Limited Warranty ...