AC E
LECTRICAL
S
YSTEM
3827 10/04
S
ECTION
3
G
ENERATOR
L
AYOUT
- G
ASOLINE
Starboard Fuel
Tank
Muffler
Fuel Solenoid
Valve
Seawater Strainer
Exhaust Thru-Hull
Fitting / Seawater
Outlet
3827-252-01
Fuel Supply Valve
Generator
Battery
Generator
Generator Battery
Master Discon-
nect Switch
Cooling System
Seacock
stops the flow of fuel to the generator if the fuel hose ruptures or
becomes disconnected. For the valve to operate properly, its manual
bypass switch, located above the starboard side of the generator,
must be “OFF.” Refer to
9.7.1
Hatches
for the exact location of this
valve.
The generator STOP/START switch is spring activated. Release the
switch from its “START” position as soon as the generator starts. If you
continue to hold the switch in its “START” position after the generator
starts, you may damage the starter.
While you are attempting to start the generator, never hold the STOP/
START switch in the “START” position for more than 10 seconds.
10. A spring-loaded generator STOP/START switch is located on the DC
Control Center. Push the switch to the “START” position and hold it
there until the generator starts. Release the switch when the gen-
erator starts.
Summary of Contents for 38 super sport
Page 1: ...38 Super Sport Owner s Guide HIN CDR 2005 Version 1...
Page 2: ......
Page 4: ......
Page 14: ......
Page 18: ......
Page 38: ...BOATING SAFETY 3827 6 04 SECTION 1...
Page 55: ...3827 10 04 DC ELECTRICAL SYSTEM SECTION 2 2 5 DC Schematic R2082D 1...
Page 56: ...DC ELECTRICAL SYSTEM 3827 10 04 SECTION 2 R2082D 2...
Page 74: ...AC ELECTRICAL SYSTEM 3827 10 04 SECTION 3 3 8 AC Schematic R2081B 1...
Page 75: ...3827 10 04 AC ELECTRICAL SYSTEM SECTION 3 R2081B 2...
Page 76: ...AC ELECTRICAL SYSTEM 3827 10 04 SECTION 3...
Page 92: ...INTERNAL SYSTEMS 3827 10 04 SECTION 4...
Page 149: ......
Page 162: ...WARRANTY AND PARTS 3827 9 04 SECTION 9 9 9 Carver Limited Warranty...