3827 10/04
AC E
LECTRICAL
S
YSTEM
S
ECTION
3
• The Main circuit breaker(s) on the AC Control Center is “ON.”
If the voltmeter continues to read zero voltage, either have a qualified
technician service your generator or contact the marina’s management to
identify and correct a shore power problem. If the problem appears to be
with your boat’s AC electrical system, have the system inspected by a
qualified electrician.
3.3.2.2 Shore #1 and #2 Polarity Indicators
These indicators show the polarity of the shore power voltage for the
Line 1 and Line 2 circuits, respectively.
If reverse polarity occurs, immediately switch the respective AC Main
circuit breaker group(s) “OFF.”
If the polarity is correct, the Safe indicator illuminates. If the polarity is
incorrect, the Reverse indicator illuminates. Refer to
3.2.1 Shore Power
for information on correcting reverse polarity.
3.3.2.3 Shore #1 and #2 Ammeters
These ammeters indicate the amount of current that is being drawn by
the Line 1 and Line 2 circuits, respectively.
When the Main circuit breaker is “ON,” all other breakers on the AC
Control Center are “OFF,” and the voltmeter is reading between 100 and
130 volts in a 120-volt system (210 and 230 volts in a 220-volt system), the
ammeter should read zero amps.
AC C
ONTROL
C
ENTER
Layout-up
Summary of Contents for 38 super sport
Page 1: ...38 Super Sport Owner s Guide HIN CDR 2005 Version 1...
Page 2: ......
Page 4: ......
Page 14: ......
Page 18: ......
Page 38: ...BOATING SAFETY 3827 6 04 SECTION 1...
Page 55: ...3827 10 04 DC ELECTRICAL SYSTEM SECTION 2 2 5 DC Schematic R2082D 1...
Page 56: ...DC ELECTRICAL SYSTEM 3827 10 04 SECTION 2 R2082D 2...
Page 74: ...AC ELECTRICAL SYSTEM 3827 10 04 SECTION 3 3 8 AC Schematic R2081B 1...
Page 75: ...3827 10 04 AC ELECTRICAL SYSTEM SECTION 3 R2081B 2...
Page 76: ...AC ELECTRICAL SYSTEM 3827 10 04 SECTION 3...
Page 92: ...INTERNAL SYSTEMS 3827 10 04 SECTION 4...
Page 149: ......
Page 162: ...WARRANTY AND PARTS 3827 9 04 SECTION 9 9 9 Carver Limited Warranty...